Technical data
22
Mobile Panel 7100 User's manual 1.51
Device with 1 enable switch
The following measures are therefore recommended for stopping the machine during manual operation:
•
Querying the enable switch when switching on the machine/system and when switching from automatic to
manual mode (the enable switch is not permitted to be in position "Enable").
•
Setting up a mechanism whereby the enable switch must be released within a predetermined period of time
and only then brought back to position "Enable". The length of this time frame can be chosen according
to the task at hand.
Device with 2 enable switches
The following measures are therefore recommended for stopping the machine during manual operation:
•
If one of the enable switches is already pressed when switching on manual operation, the enabling signal
at the output will not be enabled.
•
If an enable switch is held down in the enabling position for more than 15 minutes during operation, the
enabling signal is canceled. The enabling signal is canceled until the enable switch is released and pressed
again.