Technical data
Automation Panel 9xD - Hygienic design User's manual V 1.80
49
4.1.5.1.7 LED status indicators
LED status indicator
500 ms per interval
Assignment
LED
Color
Status
Explanation
1
2
1
2
Green
On
Power supply OK
Red
On
The system is in power saving mode (standby).
1)
Faulty or incomplete BIOS, MTCX or I/O FPGA update,
power supply OK
Faulty or incomplete BIOS, MTCX or I/O FPGA up-
date, power saving mode (standby)
Power
Red-Green Blinking
Information:
An update must be performed again.
Yellow
On
Indicates CFast access
On
Indicates an active SDL connection on the panel con-
nector.
An active SDL connection was interrupted due to pow-
er loss of the panel.
Link
Yellow
Blinking
Information:
Check the power supply or power connection of the connected panel.
Green
Blinking
Automation Runtime is starting up.
Controlled by Automation Runtime (ARemb and AR-
win).
Green
On
Application running
Controlled by Automation Runtime (ARemb and AR-
win).
Red
On
Application in SERVICE mode
Controlled by Automation Runtime (ARemb and AR-
win).
Run
Orange
Blinking
A license violation has occurred.
1)
S5: Soft-off
S4: Hibernate (suspend-to-disk)