10.3.3.1.6 Cable pinout

Field-assembled cables must be created according to the following assignment.

Information:

Functionality is only guaranteed for the cables available from B&R.

DVI (24+1), male

DVI (24+1), male

Cable shield

Cable shield

Pin

Pinout

Pin

Pinout

1

TMDS data 2 negative

13

XUSB0 positive

2

TMDS data 2 positive

14

+5 V

3

Shielding TMDS data 2 and SDL

15

GND

4

SDL negative

16

Hot plug detection

5

SDL positive

17

TMDS data 0 negative

6

DDC data

18

TMDS data 0 positive

7

DDC clock

19

Shielding TMDS data 0 and XUSB1

8

Not connected

20

XUSB1 negative

9

TMDS data 1 negative

21

XUSB1 positive

10

TMDS data 1 positive

22

TMDS data shield

11

TMDS data 1 and XUSB0 shield

23

TMDS clock positive

12

XUSB0 negative

24

TMDS clock negative

Summary of Contents for SDL4

Page 1: ...dustrial Automation GmbH is not liable for technical or editorial errors and defects in this manual In addition B R Industrial Automation GmbH assumes no liability for damages that are directly or ind...

Page 2: ...r for Automation PCs 8 3 4 Connection options 9 3 4 1 SDL4 operation 9 3 4 1 1 SDL4 operation with SDL4 Converter via SDL 9 3 4 1 2 SDL4 operation with SDL4 Converter via DVI 12 3 4 2 General limitati...

Page 3: ...40 9 2 Certifications 41 9 2 1 UL certification 41 9 2 2 EAC 41 9 2 3 KC 41 9 2 4 RCM 42 10 Accessories 43 10 1 General accessories 43 10 1 1 Accessories Order data 43 10 2 0TB103 9x 44 10 2 1 Genera...

Page 4: ...Warning Failure to observe these safety guidelines and notices can result in death severe injury or substantial damage to property Caution Failure to observe these safety guidelines and notices can re...

Page 5: ...per ESD handling Electrical assemblies with housing Do not touch the connector contacts of connected cables Do not touch the contact tips on circuit boards Electrical assemblies without housing The fo...

Page 6: ...relevant regulations e g wire cross sec tion fuse protection protective ground connection 2 6 Operation 2 6 1 Protection against contact with electrical parts In order to operate programmable logic co...

Page 7: ...s and security solutions are suitable for this purpose Segmentation of the network e g separation of the IT and OT networks Firewalls for the secure connection of network segments Implementation of a...

Page 8: ...with an SDL4 inter face or SDL4 slot This makes it easy to upgrade systems to SDL4 as part of retrofit measures and conversions When combined with an SDL4 interface integrated on a B R industrial PC...

Page 9: ...connected to the SDL4 Converter using an SDL3 SDL4 cable the maximum SDL4 cable length is 100 m In addition to the display data information from the touch screen matrix keys LEDs and service diagnost...

Page 10: ...t SDL4 Converter USB type A B cable SDL cable Availability of interfaces on the Automation Panel with SDL4 receiver SDL4 interface USB1 USB2 USB 2 0 Power supply Grounding Maximum cable length for SDL...

Page 11: ...l PC Power supply SELV PELV SDL3 SDL4 cables Automation Panel with SDL4 receiver 1 port SDL4 Converter SDL cable Industrial PC Power supply SELV PELV Automation Panels with SDL4 receivers SDL3 SDL4 ca...

Page 12: ...en the industrial PC and SDL4 Converter 5COSD4 1000 00 5COSD4 1001 00 is 5 m USB 2 0 is transferred via an external USB type A B cable Industrial PC Power supply SELV PELV SDL3 SDL4 cables Automation...

Page 13: ...System overview SDL4 Converter User s manual V 2 00 Translation of the original documentation 13 Firmware updates are not possible Adjusting the display brightness is not possible...

Page 14: ...point analysis It is possible to analyze the number and type of endpoints on a particular USB device Third party USB analysis tools can be used for this purpose The SDL4 connection has a limited numbe...

Page 15: ...imum of seven additional USB devices can be connected Maximum permissible USB endpoints Endpoints Transfer rate of the devices IN OUT High speed 11 12 Full speed Low speed 12 12 Multi touch panels The...

Page 16: ...5CASDL 0008 00 5CASDL 0018 00 5CASDL 0050 00 5CASDL 0060 00 5CASDL 0100 00 SDL cables with 45 connector 5CASDL 0018 01 5CASDL 0050 01 5CASDL 0100 01 SDL flex cables 5CASDL 0018 03 5CASDL 0050 03 5CASD...

Page 17: ...clamp terminal block 3 31 mm SDL cables 5CASDL 0008 00 SDL cable 0 8 m 5CASDL 0018 00 SDL cable 1 8 m 5CASDL 0050 00 SDL cable 5 m 5CASDL 0060 00 SDL cable 6 m 5CASDL 0100 00 SDL cable 10 m SDL3 SDL4...

Page 18: ...degree 2 Degree of protection per EN 60529 IP20 Ambient conditions Temperature Operation 0 to 55 C 2 0 to 45 C 2 Storage 20 to 60 C Transport 20 to 60 C Relative humidity Operation 5 to 90 non conden...

Page 19: ...nformation All specifications in dimension diagrams and associated tables are in millimeters mm 2D and 3D diagrams DXF and STEP formats can be downloaded from the B R website www br automation com 5CO...

Page 20: ...00 View A View B A B Figure 3 5COSD4 1000 00 Device interfaces overview Legend 1 LED status indicators on page 24 4 24 VDC power supply on page 21 2 SDL DVI In interface on page 22 5 Grounding on page...

Page 21: ...n Figure 1 2 Functional ground 3 Reverse polarity protection 3 pin Male Electrical properties Nominal voltage 24 VDC 25 SELV1 Nominal current 5COSD4 1000 00 Max 0 3 A Nominal current 5COSD4 1001 00 Ma...

Page 22: ...DL transfer The following table shows the relationship between segment length and maximum resolution depending on the SDL cable Resolution SDL cable Segment length m VGA 640 x 480 SVGA 800 x 600 XGA 1...

Page 23: ...proved operating systems Recalibration may be required for touch screen de vices A maximum of 500 mating cycles are specified for this interface 3 6 2 1 5 USB In interface The USB In interface is a US...

Page 24: ...nvalid or incomplete firmware upgrade is indicated Information The firmware upgrade must be per formed again Status Red On Firmware upgrade is in progress On The SDL and SDL4 connection is established...

Page 25: ...1 SDL cable 45 degree connector 5 m 51 5CASDL 0100 01 SDL cable 45 degree connector 10 m 51 SDL cables 5CASDL 0008 00 SDL cable 0 8 m 48 5CASDL 0018 00 SDL cable 1 8 m 48 5CASDL 0050 00 SDL cable 5 m...

Page 26: ...ating or servicing the device or using accessories e g cable strain relief clips this must be taken into account during installation Legend 1 Air outlet 2 Air inlet Spacing Description Dimension Descr...

Page 27: ...iggered ADI sensors Max specified temperature C SDL4 Converter sensor 1 90 SDL4 Converter sensor 2 100 Table 6 Temperature sensors 4 2 1 Reading temperature values The temperatures can be read from ap...

Page 28: ...nd from the power supply All covers and components accessories hardware and cables must be installed or secured before the device is connected to the power supply and switched on Installation Informat...

Page 29: ...storage When transporting at low temperatures or in the event of large temperature fluctuations the collection of moisture in or on the device is not permitted Moisture can cause short circuits in ele...

Page 30: ...onverter The frame on the back of the device allows the system to be installed on a top hat rail TS35 that corresponds to the EN 50022 standard 35 1 7 5 Figure 6 Top hat rail 5 2 1 Procedure 1 Attach...

Page 31: ...nverter according to the following figure and secured with the supplied locating screws M3 max tightening torque 0 5 Nm The length overhang is not permitted to be removed and the cable strain relief c...

Page 32: ...rrupted Before connecting the DC power cable it must be checked whether it has been disconnected from the voltage source e g power supply 5 4 1 1 Wiring Install the DC power cable on the terminal bloc...

Page 33: ...must be interrupted Before connecting the power cable it must be checked whether it has been disconnected from the voltage source e g power supply 1 Carry out electrostatic discharge on the housing or...

Page 34: ...he following points must be observed to ensure that electrical interference is safely diverted Connect the device to the central grounding point e g the control cabinet or the system using the shortes...

Page 35: ...ion PC via SDL4 instead of SDL The Cat 6 Cat 7 cables used with SDL4 are much easier to install and connect When connecting or installing cables the bend radius specification must be observed For this...

Page 36: ...ranslation of the original documentation 5 6 Removing the SDL4 Converter 5 6 1 Procedure 1 Pull the SDL4 Converter downwards 1 and slightly in the opposite direction away from the top hat rail 2 This...

Page 37: ...rdware the device must have been started up Caution Before the device is started up it must be gradually adapted to room temperature Exposure to direct heat radiation is not permitted When transportin...

Page 38: ...te www br automation com 7 1 1 Firmware upgrade To upgrade the firmware an APC910 PPC900 APC2200 or APC3100 PPC3100 with compatible MTCX firmware must be connected in addition to an Automation Panel w...

Page 39: ...ermitted to be used for maintenance work 8 1 Repairs Complaints and replacement parts Danger Unauthorized opening or repair of a device may result in personal injury and or serious damage to property...

Page 40: ...nts of EU directive Electromagnetic compatibility 2014 30 EU and are designed for industrial applications EN 61131 2 2007 Programmable controllers Part 2 Equipment requirements and tests EN 61000 6 2...

Page 41: ...ertificates 9 2 1 UL certification Ind Cont Eq E115267 Products with this mark are tested by Underwriters Laboratories and listed as indus trial control equipment The mark is valid for the USA and Can...

Page 42: ...ation of the original documentation 9 2 4 RCM Products with this mark are tested by an accredited test laboratory and certified by the ACMA The mark is valid for Australia Oceania and facilitates the...

Page 43: ...observed when operating the complete system All components listed in this manual have undergone intensive system and compatibility testing and been approved accordingly B R cannot assume any functiona...

Page 44: ...o 100 Vibration A 0 7 g EMC B bridge and open deck 2 Terminal block Note Protected against vibration by the screw flange Nominal data per UL Number of pins 3 female Type of terminal block Screw clamp...

Page 45: ...fer from those of the complete system The data specified for the complete system applies to the complete system in which this accessory is installed for example Model number 5CASD3 0030 00 5CASD3 0050...

Page 46: ...erly connected Ambient conditions Temperature Storage 40 to 70 C Fixed installation 40 to 70 C Flexible installation 40 to 70 C 10 to 50 C Mechanical properties Dimensions Length 3 m 5 m 10 m 15 m 20...

Page 47: ...n wh or bl wh bl or wh br br Shield 10 3 1 1 7 Wiring The following information and figure apply if a field assembled cable is used and connected to an RJ45 network connector e g patch panel instead o...

Page 48: ...the complete system in which this accessory is installed for example Model number 5CASDL 0008 00 5CASDL 0018 00 5CASDL 0050 00 5CASDL 0060 00 5CASDL 0100 00 General information Certifications CE Yes U...

Page 49: ...206 g Approx 300 g Approx 580 g Approx 700 g Approx 1500 g Table 12 5CASDL 0008 00 5CASDL 0018 00 5CASDL 0050 00 5CASDL 0060 00 5CASDL 0100 00 Technical data 1 Yes but applies only if all components...

Page 50: ...ble shield Pin Pinout Pin Pinout 1 TMDS data 2 negative 13 XUSB0 positive 2 TMDS data 2 positive 14 5 V 3 Shielding TMDS data 2 and SDL 15 GND 4 SDL negative 16 Hot plug detection 5 SDL positive 17 TM...

Page 51: ...this accessory is installed for example Model number 5CASDL 0018 01 5CASDL 0050 01 5CASDL 0100 01 General information Certifications CE Yes UL cULus E115267 Industrial control equipment HazLoc cULus H...

Page 52: ...01 5CASDL 0050 01 5CASDL 0100 01 Technical data 1 Yes but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark 2...

Page 53: ...ble shield Pin Pinout Pin Pinout 1 TMDS data 2 negative 13 XUSB0 positive 2 TMDS data 2 positive 14 5 V 3 Shielding TMDS data 2 and SDL 15 GND 4 SDL negative 16 Hot plug detection 5 SDL positive 17 TM...

Page 54: ...umber 5CASDL 0018 03 5CASDL 0050 03 5CASDL 0100 03 General information Certifications CE Yes UL cULus E115267 Industrial control equipment HazLoc cULus HazLoc E180196 Industrial control equipment for...

Page 55: ...t ed 300000 cycles at 15x cable diameter 4800 cycles hour Drag chain data Flex cycles 300 000 Speed 4800 cycles hour Bend radius 180 mm 15x cable diameter Hub 460 mm Weight Approx 460 g Approx 1020 g...

Page 56: ...tructure 5CASDL 0xxx 03 Element Pinout Cross section TMDS data 0 26 AWG TMDS data 1 26 AWG TMDS data 2 26 AWG DVI TMDS clock 26 AWG XUSB0 26 AWG USB XUSB1 26 AWG Data SDL 26 AWG DDC clock 24 AWG DDC d...

Page 57: ...ble shield Pin Pinout Pin Pinout 1 TMDS data 2 negative 13 XUSB0 positive 2 TMDS data 2 positive 14 5 V 3 Shielding TMDS data 2 and SDL 15 GND 4 SDL negative 16 Hot plug detection 5 SDL positive 17 TM...

Page 58: ...Yes UL cULus E115267 Industrial control equipment DNV GL Temperature B 0 55 C Humidity B up to 100 Vibration A 0 7 g EMC B bridge and open deck 1 GOST R Yes Cable construction Wire cross section 28 A...

Page 59: ...n 59 10 3 5 1 4 Bend radius specification Connector Ferrite bead Ferrite bead Ferrite bead Bend radius Connector Ferrite bead Bend radius Ferrite bead Ferrite bead Figure 20 Bend radius specification...

Page 60: ...10 3 5 1 6 Cable pinout If you wish to assemble a suitable cable yourself the cable must be wired according to this pinout Information Functionality is only guaranteed for the cables available from B...

Page 61: ...ied for the complete system applies to the complete system in which this accessory is installed for example Model number 5CAUSB 0018 00 5CAUSB 0050 00 General information Certifications CE Yes UL cULu...

Page 62: ...10 3 6 1 4 Cable pinout If you wish to assemble a suitable cable yourself the cable must be wired according to this pinout Information Functionality is only guaranteed for the cables available from B...

Page 63: ...the cable strain relief clip on page 31 10 4 2 Order data Model number Short description Figure Accessories 5ACCRHMI 0011 000 REP strain relief USB For APC2100 APC2200 For SDL3 Con verter SDL4 Conver...

Page 64: ...possible 11 1 Separation of materials To ensure that devices can be recycled in an environmentally friendly manner it is necessary to separate out the different materials Component Disposal Programmab...

Page 65: ...Publishing information SDL4 Converter User s manual V 2 00 Translation of the original documentation 65...

Page 66: ...nverter User s manual V 2 00 Translation of the original documentation Publishing information B R Industrial Automation GmbH B R Strasse 1 5142 Eggelsberg Austria Telephone 43 7748 6586 0 Fax 43 7748...