P/N: 68060189011 Rev.A
Appendix A:
Installation Guide for Vehicle Usage.
K530 series router is designed for rugged mobile field use that meets
MIL810G military standard for drops, vibration, humidity,
and extreme temperatures. To ensure proper operation of K530 series
router,
Please consider below guidelines for optimal vehicle installation.
Location and Cable wiring
Place the router as close as possible to the voltage regulators such as
power management block and filters. Keep the power cables short
between device and output connectors of the voltage regulators.
Use proper wire size according to expected current load.
A dedicated ground wire is highly recommended instead of direct
attachment to chassis ground.
To minimize noise interference, a filter can be applied to isolate the
router from other electrical devices.
5
AWG Rating
Electric Current Load (Amps) 10-Feet Cable 20-Feet Cable
3-10 14 AWG 12 AWG
11-20 14 AWG 10 AWG
21-35 8 AWG 6 AWG