Compulsory Warranty Requirements 
Essential to maintain Manufacturers Product Warranty,  Public Liability & Product Efficacy Insurances, and 
to comply with EN50131-8 Standards 
 
1. 

Battery Change - Every 2 Years 

 

 

(estimated time required 25 – 30 minutes)

 

 

 

Conduct the optional annual requirements listed  

above PLUS replace the 

BANDIT

’s internal rechargeable battery, 

which is located underneath the HY-3 Fluid Cylinder, in the  
Bandit’s side compartment. Removal of the HY-3 Cylinder  
will be required to gain access to the battery. 

 

 

The Bandit’s internal rechargeable battery is a standard ‘alarm system’ sealed lead-acid cell type, 
approx. dimensions 178mm x 60mm x 34mm (exact dimension vary slightly between manufacturers), 
and is 12 volts, 2.1 Ah rated. 
 

 

IMPORTANT! – Make sure that the battery terminal wires are connected the correct way round – 
failure to do so may result in component damage! 
 

 

 

2. 

HY3 Fog Fluid Cartridge Change - Every 4 Years (Required)

 

 

 

(estimated time required 30 – 35 minutes) 

 

 

In addition to the ‘every 2 years’ requirements above it is 
recommended that HY-3’s are returned to the manufacturer 
for a service check every 4 years from the time they are first 
installed.  Simply exchange the customers HY-3 with a freshly 
serviced and filled unit and return the original to Bandit UK. 
The customer is charged the standard refill cost of the cartridge 
+ time on site. 

 

HOW TO REPLACE THE HY-3 FLUID CYLINDER FOR A BANDIT 240 DB SECURITY FOGGING UNIT 

 
 

POINTS TO NOTE BEFORE YOU START: 

 

As long as your Fog Bandit is not ‘set’ (i.e., ‘Guard’ light on the front is not on) the HY-3 Fluid Cylinder 
can be replaced without the possibility of a fog ejection. 
 

 

The action of removing the side compartment cover will create a ‘Tamper’ signal, which may be 
detected by your intruder alarm system.  If this occurs, simply re-set your intruder alarm system using 
your normal method once you have completed the cylinder exchange.  If your Bandit is not alarm 
connected but stand alone, simply reset the FMU (Fault Module Unit) in the same manner.  You will 
also hear an internal fan operate for a few seconds when the cover is opened and when subsequently 
closed again – this is perfectly normal and occurs due to the ‘Tamper’ notification being detected. 
 

 

In the following images, the Fog Bandit is shown disconnected from its mounting bracket so as to 
provide clear images of the process.  You do not have to do anything to your Bandit other than remove 
the side panel so as to access the cylinder compartment and follow the instructions provided.  

 