background image

BA230

33

UK

MENU C: FUNCTIONS SELECTIONS

KEY + enters the following menu  C1-C2-C3-…
KEY – enters the previous menu C3-C2-C1…
KEY ESC leaves the menu
KEY OK  enables Y (yes). It enables or selects the function 
KEY OK  enables N (no). It disables the function

Description

Menu

Function

Status

Enables automatic closing after both complete opening and pedestrian 
opening.

Enables only  automatic closing after a complete opening.
If pedestrian opening is enabled, the pedestrian key will close the gate.

Enables only  automatic closing after a pedestrian opening.

Disables automatic closing
If the pedestrian opening is enabled, the pedestrian key will close the 
gate.
If complete opening is enabled, a Start command will close the gate and 
the pedestrian key will be uninfluemtial.

AUTOMATIC CLOSING

C1

YT

YS

YP

N

Enables the safety devices test
When  the  device  is  enabled  (edge  intercepted),  the  writing 

SAF

 

appears on the LCD

Operation:

PHASE  1:  when  the  Start  or  the  Pedestrian  command  is  given,  the 
electronic circuit is tested: relay, triac, etc. 
If an anomaly is detected, it will be indicated by 4 long flashes (2 sec.) of 
the  flashing  light. The  test  must  be  performed  when  the  motors  are 
connected.
If the control unit is set for one motor, the test will be performed only for 
motor 1 circuit.

WARNING: During the test, the motors will be activated in opening and 
closing for about 300 msec. 
DUE  TO  THE  MOTION,  THE  DOOR  MAY  CRASH  AGAINST  THE 
MECHANICAL STOPS. CHECK THE SYSTEM SAFETY/INTEGRITY 
AFTER THIS PHASE. 

SAFETY DEVICES TEST 

See also menu C20

C4

Y

Enables fast closing function

Operation:

Enabled only on photocell 1.
Reduces  pause  time  to  3  s  following  interception  and  subsequent 
freeing of the photocells.

Enables 3-second pre-flashing before motors start

Disables fast closing function

Disables  pre-flashing. The  flashing  light  and  the  motors  start  at  the 
same time.

FAST CLOSING

PRE-FLASHING

C2

C3

Y

Y

N

N

The opening and closing movement in the dead man's mode stops 
always on the first limit switch.
The possible regulations are: PHASE SHIFT IN OPENING - PHASE 
SHIFT IN CLOSING.
The enabling of this menu automatically disables A6-A7-A8.

DEAD MAN LOGIC

A9

Y

Summary of Contents for GiBiDi BA230

Page 1: ...BA230 I UK F E GR D P NL BA230 AS05550 Apparecchiatura elettronica ISTRUZIONI PER L INSTALLAZIONE Electronic control unit INSTRUCTIONS FOR INSTALLATIONS...

Page 2: ...i S r l se reserva el derecho de modificar los datos t cnicos sin previo aviso en funci ndelaevoluci ndelproducto POR FAVOR LEER CON ATENCI N ESTE MANUAL ANTES DE PROCEDER CON LA INSTALACI N Dieses Pr...

Page 3: ...OSE LAMP MOTOR OPEN LAMP MOTOR COM MOTOR CLOSE MOTOR OPEN MOTOR COM JP5 COM EL EL1 EL2 GND SPIA 24Vcc SEC JP1 C8 RL1 RL2 L1 C2 CF1 CF3 RL4 RL5 RL3 RL6 RL7 CF4 CF2 CF6 CF5 U2 U5 BA230 CM2 CM1 DL1 DL2 D...

Page 4: ...start pulse the motion restarts in the obstacle freeing direction SEPARATE SAFETY DEVICES POWER SUPPLY The connection to this power supply will allow the TEST of the devices before the motion Connect...

Page 5: ...away from children since they pose a potential risk The manufacturer declines all responsibility for improper functioning of the automated device if the original components and accessories suitable f...

Page 6: ...OPEN Common motor 2 11 COM Motor 2 connection closing 12 CLOSE JP5 Negative electrical lock 13 COM Positive 12 Vdc motor 1 electrical lock 14 EL1 Positive 12 Vdc motor 2 electrical lock 15 EL2 Negati...

Page 7: ...tion Inputenabledduringbothopeningandclosing It stops and inverts the motion for 2 s The gate will remain locked until the next Start pulse whichwillmakeitstartintheobstacle freeingdirection Ifthe inp...

Page 8: ...willbeloaded onlytheperformedcyclessettingsremainstored PresstheESCkeytogobacktostep1 4figuresappearonthedisplay 0000 thefirstoneisflashing With the or keys the user selects the first digit of the in...

Page 9: ...onthedisplay lettersACFHE theAis flashing Use the or keys to select the other menus the relative letter will blink PressOKtoentertheselectedmenu intheexample menuA Usethe or keystoenterthesubmenus A1...

Page 10: ...seethesettingofanumericvalue Usethe and toselectthemenuH itwillblink PressOKtoenterthemenu Use the or keys to select the submenus Press key to enter the selected submenu Thestoredvalueappears withthef...

Page 11: ...bletheinput TheNwillappearnexttoE1 Usethe and keystoenterthefollowingorthepreviousmenu PressESCtoleavethemenu ACFHE isnowshownonthedisplay E2 PHOTOCELL2 PressOKinsequenceto Enabletheinput theYwillappe...

Page 12: ...IC LOCK 2 output see diagram 12 Vdc output Thecourtesylightoutputis3 minutestimed TheactivationofthismenuautomaticallydisablesA5 1 MOTOR CONFIGURATION A4 Y MENU A SYSTEM CONFIGURATION AND OPERATING LO...

Page 13: ...te Pedestriancommandisuninfluentialinopeningandinpause Inclosing itopensbothleaves TheactivationofthismenuautomaticallydisablesA6 A8 A9 ItenablestheSTEPBYSTEPWITHSTOPLogic Operation Start NextStart Ne...

Page 14: ...given the electroniccircuitistested relay triac etc If an anomaly is detected it will be indicated by 4 long flashes 2 sec of the flashing light The test must be performed when the motors are connect...

Page 15: ...TEST See also menu C20 LIMIT SWITCHES DECELERATIONS WATER HAMMER C4 C5 C6 C7 Y E1 Y1 Y1 Y2 E2 Y2 N Y3 N Disablesthesafetydevicestest N The exclusion of SAFETY DEVICE by mean of the menu E3 excludes t...

Page 16: ...ation with the same setting of menusF2andF6 During the PEDESTRIAN closing the PHOTO1 PHOTO2 PEDESTRIAN STARTcommandwillcausethecompleteopening Flashinglightfixedoutput DisablestheRESERVEinput NC N YF...

Page 17: ...safety devices is cut off for 0 5 and then restored if the photocell 1 input opens and immediately returns NCthe motorsstart otherwise a fault will besignalledby4blinks 1sec oftheflashinglight Enables...

Page 18: ...IC CLOSING PAUSE TIME Determines the pause time in opening before the automatic closing Tmax 300 s PEDESTRIAN OPENING TIME Determines the pedestrian opening time Tmax 300 s AUTOMATIC PEDESTRIAN CLOSIN...

Page 19: ...means of sequences of START pulses Select the menu C21 to enter this procedure menu C21 blinking The times learning procedure starts by pressing OK menu C21 Y fixed then TIMES MANAGEMENT TIMES LEARNI...

Page 20: ...instalment is configured as double sliding the motors will move as indicated in the procedure with the phase shift in opening and closing During normal working phase shifts are zeroed RESET FLASHING...

Page 21: ...ENERAL AND PEDESTRIAN AUTOMATIC CLOSING ENABLED N FAST CLOSING DISABLED C3 Y PREFLASHING ENABLED C4 N SAFETY DEVICES TEST DISABLED C5 E1 LIMIT SWITCH ENABLED single pair C6 N DECELERATIONS DISABLED C7...

Page 22: ...ections improper connection may be harmful to both the control unit and the operator 2 Check proper position of the limit switches POWER THE DEVICE 3 Check that the red LEDs of the normally closed con...

Page 23: ...re Go to menu C6 to program slowdowns Use the dedicated menus to adjust each time parameter Press ESC to exit programming Check whether the force used by operators on the gate is either sufficient or...

Page 24: ...products ELECTRONIC CONTROL UNIT BA230 are in conformity with the following CEE Directives EMC Directive 2004 108 CE and subsequent amendments and that the following harmonised standards have been ap...

Page 25: ...DI S r l 46025 Poggio Rusco MN ITALY Tel 39 0386 52 20 11 Fax 39 0386 52 20 31 E mail comm gibidi com Numero Verde 800 290156 Via Abetone Brennero 177 B w w w g i b i d i c o m Cod AIC6509 02 2009 Re...

Reviews: