MENU C: FUNCTIONS SELECTIONS
KEY + enters the following menu C1-C2-C3-…
KEY – enters the previous menu C3-C2-C1…
KEY ESC leaves the menu
KEY OK enables Y (yes). It enables or selects the function
KEY OK enables N (no). It disables the function
Description
Menu
Function
Status
Enables automatic closing after both complete opening and pedestrian
opening.
Enables only automatic closing after a complete opening.
If pedestrian opening is enabled, the pedestrian key will close the gate.
Enables only automatic closing after a pedestrian opening.
Disables automatic closing
If the pedestrian opening is enabled, the pedestrian key will close the
gate.
If complete opening is enabled, a Start command will close the gate and
the pedestrian key will be uninfluemtial.
AUTOMATIC CLOSING
C1
YT
YS
YP
N
Enables the safety devices test
When the device is enabled (edge intercepted), the writing
SAF
appears on the LCD
Operation:
PHASE 1: when the Start or the Pedestrian command is given, the
electronic circuit is tested: relay, triac, etc.
If an anomaly is detected, it will be indicated by 4 long flashes (2 sec.) of
the flashing light. The test must be performed when the motors are
connected.
If the control unit is set for one motor, the test will be performed only for
motor 1 circuit.
WARNING: During the test, the motors will be activated in opening and
closing for about 300 msec.
DUE TO THE MOTION, THE DOOR MAY CRASH AGAINST THE
MECHANICAL STOPS. CHECK THE SYSTEM SAFETY/INTEGRITY
AFTER THIS PHASE.
SAFETY DEVICES TEST
See also menu C20
C4
Y
Enables fast closing function
Operation:
Enabled only on photocell 1.
Reduces pause time to 3 s following interception and subsequent
freeing of the photocells.
Enables 3-second pre-flashing before motors start
Disables fast closing function
Disables pre-flashing. The flashing light and the motors start at the
same time.
FAST CLOSING
PRE-FLASHING
C2
C3
Y
Y
N
N
The opening and closing movement in the dead man's mode stops
always on the first limit switch.
The possible regulations are: PHASE SHIFT IN OPENING - PHASE
SHIFT IN CLOSING.
The enabling of this menu automatically disables A6-A7-A8.
DEAD MAN LOGIC
A9
Y