| 79
Installation |
V90S User Manual
Connector 1 - Fuse
Install a 10 Amp MINI
®
blade fuse.
Connector 2 - Power connection
Label
Wire colour
VCC
Red
GND (Negative)
Black
¼
Notes:
•
Voltage: 12 VDC (10.8 VDC to 15.6 VDC)
•
2 m twin-core power cable is supplied
•
If you need to shorten the power cable, ensure that the two
ferrite cores are moved and installed on the shorter cable.
Connectors 3, 4, 5 and 6 - Wired handsets
Number
Label
Wire colour
1
GND
Black
2
TX/RX_A
Blue
3
TX/RX_B
Green
4
VCC
Red
5
POWER-SW
White
6
PTT
Grey
7
MIC_AF-
Yellow
8
Orange
¼
Notes:
•
All the necessary wires are included in the handset cable
supplied.
•
The wired handset cable includes a connector assembly that
must be installed in a bulkhead, dashboard or other suitable
panel.