• When not in use, store the gun so that the plunger rod will

not be damaged or bent.

Note:

Always start with a fresh bait tube each day.  Over

time, when exposed to air, some baits tend to solidify and
make the gun difficult to operate.

Damaged Plunger Rod

• To replace the rod, 

do not

take the gun apart.

• Unscrew and remove the end of the plunger rod, then lightly

press the release knob and pull the rod out of the back of
the gun

• Insert new rod carefully through back of the gun, then at-

tach the tip of the rod.

Suggested Uses

Trouble Shooting

Operating Instructions

Operation

MULTI-DOSE BAIT GUN

USER’S MANUAL

Problem:

Syringe does not hold securely to gun

Solution:

• Check for o-ring, replace if missing.

Problem:

No bait delivered with trigger pull

Solution: 

• Check the tip of the syringe for dry bait plug;

check the position of the plunger rod against the
back of the syringe.

Problem:

Bait continues to drip after trigger pull

Solution:

• Select a lower setting.

• Always wear personal protection equipment required

by the insecticide label.

• Keep cap on bait tubes not in use and while 

transporting the bait gun.

• Always follow label directions on gel bait 

insecticides for use and disposal of empty syringes.

• The Plunger Rod does not

need oil or any lubrication.

• The addition of oil to the

Plunger Rod will result in
dirt sticking to it and block-
ing movement.

• For the application of paste or gel formulations of

insecticides.

• Setting 1-4 are calibrated for syringes with paste

or gel formulations.

Before Starting

• Be sure the plunger rod moves smoothly and is not bent.

• Push the rod release lever forward to move the plunger to

the base of the gun.

Settings #4 – This setting will 
deliver the 0.50 gram place-
ment recommended by the
label on Advance, Advion,
Alpine, and Vendetta. Two 
(1 gram) or three (1.5 grams)
trigger pulls will deliver the
large placements for Maxforce.

Care and Maintenance

Plunger Rod Maintenance

Attach Syringe

• Retract the plunger to the base of the gun.

• Place the syringe between the locking tabs and twist to the

right.

Select Setting

• Select the setting (1-4) by pulling the

adjustment knob out and turning to the
right or left.

• Align number with the triangle point on

the side of the gun.

Safety Precautions

24020200   Rev 7/12

Setting #1 – This setting will deliver
the 1/4 inch or the 0.25 gram place-
ment recommended by all the major
gel-bait products, including Advance,
Advion, Alpine, Invicta, Maxforce, and
Vendetta.

Setting #2, 3 - This setting typically delivers 0.35 grams of
bait, depending on the product.

For Multi-Dose Guns purchased after August 2012
 

Reviews: