PART NO: 51621. REVISION 6 - OCTOBER 2016
a) Check that curtain overlaps equally on
both sides.
b) Check that guides are the correct
length, that is, level with the brackets
(or in the restricted headroom position
are 35mm maximum above bracket).
NOTE:
Restricted headroom is not
recommended when fitting an opener.
c) Slide half the number of guide clips into
each guide.
d) Position the bottom clip 200mm from
the floor with the rest evenly spaced
along the guide. (Hint: to prevent clips
from sliding down the guide, temporarily
secure them with adhesive tape.) Now
position one guide over the edge of the
door curtain.
e) Mark and drill the top fixed guide clip and
secure using a 40mm x 8mm coach screw
and washer, allowing 3mm clearance
between the inside of the guide and
plastic roller guide block.
f) Ensuring guide is plumb, drill and fix
remaining clips. (
NOTE:
if securing to
uneven brickwork, packers may be
required behind clips, to prevent them
twisting out of square; also ensure that clips
are positioned on secure bricks).
g) With the top of the 2nd guide level with the
first, repeat (e) and (f).
h) Remove the chock and slowly lower the door
removing plastic wrap as you pull door down,
reposition the guides as necessary to allow
smooth and even operation with 0>1mm
clearance throughout.
i) Ensure door curtain enters guides smoothly. It
will be necessary to adjust the guide lead in
to achieve this.
1
WOOD CHOCK
ROLL-A-GUIDE
RESTRICTED HEADROOM 35mm
SPACE
EVENLY
GUIDE
CLEARANCE
0>1mm
GUIDE BLOCK
200mm
DOOR
CURTAIN
BOTTOM RAIL
BOTTOM RAIL LIP
STOP
(a)
(a)
(b)
(c)
(e)
(d)
(b)
2
NYLOFELT
GUIDE LEAD IN
(i)
HOOK
THIS END FIRST
LOCK C ORRUGATIO N
(c)
DOUBLE SIDED
ADHESIVE TAPE
LOCK BAR C OVER
LOCK BODY
LOCK ARM
CUT-
LOCK BAR C OVER
FACEPLATE
(c)
(g)
(f)
(i)
(d)
LOCK BAR
2.7 guides
10
Firmadoor
®
Series 1 Installation Instructions