Controll-A-Door
™
A U T O M A T I C G A R A G E D O O R O P E N E R
POWER
CODE SET
LIMIT SET
WARNING:
Cover not to be removed except by
authorised technician
Power
LED
Manual Operation
Use caution when operating the manual release with the door open since it may fall
rapidly due to weak or broken springs, or an imbalanced door.
AS3350
Caution: Do not disengage the opener to manual operation with children/persons or
any objects including motor vehicles within the doorway.
To disengage the opener from the door, (preferably with the door in the closed
position) pull down on the disengagement handle - you will hear a ‘click’.
Pulling down on this handle again (click) will re-engage the opener,
i.e. automatic operation.
You may manually open or close the door any time without affecting the pre-set limits.
Warning: When the opener is manually disengaged,
the door is no longer locked. When the door is
closed you should either :
a. Re-engage the opener, or
b. Use the manual locking bars if fitted to the door.
Power Failure
When there is a power failure, the opener will be unable to automatically open
or close your garage door. To use your door whilst there is no power you will
need to disengage the opener and use the door manually - see Manual Operation.
When the power resumes your opener will be automatically reset. The Code
Set and Limit Set LED’s will flash for a few seconds whilst the opener
undergoes a self-test. The Power LED will then come on, returning
your opener to normal operation.
Safety Infra Red Beam Option
A B&D Safety Infra Red Beam Kit (Part No 62153) may be fitted to this opener.
•
When this option is fitted and selected, the operation of this device is such that if an object (i.e. car, child, etc)
blocks the infra red beam, then the door will not close.
•
When the Infra Red dipswitch is activated, the Safety IR Beam accessory must be fitted and functional.
•
If the switch is activated and a Safety IR Beam is not fitted or not operating then the door, once opened, cannot
be closed. The relays will click twice when attempting to operate the opener to indicate this condition.
Auto Close Option
To have the Auto Close option you must also have a B&D Safety Infra Red Beam (Part No 62153) fitted and
functioning. When this option is selected the door will attempt to close automatically 30 seconds after opening. If
repeatedly prevented by an obstruction the opener will cease auto closing after the fourth attempt. Once the
obstruction is cleared, press the operate button to activate the opener.
Remote Control Transmitter Battery
When necessary, remove the cover and replace the battery. Dispose of the old battery properly.
Page 16
©Copyright 2001
B&D Australia