1. Check the proper supply for such characteristics as correct voltage, phase, and cycles to be
certain they are correct for the machine.
2. Open manual shut-off water valves to the machine.
3. Press Emergency Stop button.
4. Apply power to the machine.
5. Release the Emergency button.
6. Check the door interlock before starting the machine.
(a) Attempt to start the machine with the door open. The machine should not start with the
door open.
(b) Close the door without locking it and attempt to start the machine. The washer should
not start with the door unlocked.
(c) Close and lock the door and start a cycle. Attempt to open the door while the cycle is in
progress. The door should not open. If the door lock and interlock are not functioning
properly, call a service technician.
7. For testing, select program 30 by pressing key 3 and key 0 on the keypad. Then press ENTER
followed by the START key. Run the complete program, checking operation of water inlet
valves, drain, and extract functions. Program 30 is a test program that goes through most
machine functions. Please note that the Spin 99 routine is
designed to fail balance
. Simply
advance the program to the Spin 3 cycle after balance fails (use the appropriately named
ADVANCE key). Refer to the EL6 Stock Program Listing that came with the machine for
further details on the test program.
8. Cylinder rotation must be counter-clockwise in the extract step. If rotation is not correct,
disconnect the power to the machine. A qualified technician must reverse any two leads
between the AC drive and the motor. See figure 5.11 on page 31.
Figure 5.11: Inverter Drive to Motor Detail
31
Summary of Contents for SI Series
Page 1: ...Washer Extractor SI Series Installation and Operation Manual 9 Sep 2013 Revision 2 20 ...
Page 6: ...Figure 1 1 SI Product Family 2 ...
Page 14: ...Chapter 4 General Specifications 10 ...
Page 15: ...Figure 4 1 SI Series General Specifications 11 ...
Page 33: ...Figure 5 9 Loading Chute Installation 29 ...
Page 34: ...Figure 5 10 Loading Chute Up Switch Installation 30 ...