Execution
Wash Program Execution
23
Partial Program
A program can be partially run. After selecting
the program you wish to execute, the display
will show:
Instead of pressing ENTER to execute the
program, press the ADVAN key. The cycles
within the program will be displayed
incrementally. Choose the point at which you
would like to begin, and press the START key.
The machine will begin operation from this
point.
Displaying the Current
Program and Step
While the machine is in operation, pressing
then ENTER key will cause the display to show
the current program number and step.
PRG 1 STP 3
Soak
You can insert a pause at any point of the wash
program with the exception of distribution and
spin. To do so, simply press the PAUSE key.
The display will begin showing a time, counting
up as long as the machine remains paused.
Pressing the START key will restart the program
at the point it was paused. As long as the
machine is paused, all other WDT (watch dog
timers) are paused as well.
Advance
While any program is running, you can end the
current step and advance to the next one by
pressing the ADVAN key. If the key is pressed
during a spin, the spin will be aborted, and the
standard spin slow down time will be activated.
Halting a Program
At any time during the execution of the wash
program, the running program can be
terminated by pressing the STOP key.
Water Level Refresh
While a program is running, if the water level
drops to a level which is 3cm below the target
level, cold water will automatically be added to
replenish the level.
Spin Retry
If, during a spin segment, the load is excessively
out of balance, the spin will stop, and a
redistribution of the goods will take place. If
three consecutive out of balances occur, the
machine will end the program.
Power Failure
If the power fails during execution of a
program, and is of less than one second, it is
ignored. If the failure is longer than one
second, the machine stops. Upon restoration of
mains power, the display shows CYCLE
CONTINUE? If you wish to restart the program
at the point in which power failed, press the
START key. At this point, the program restarts
at the point of power failure and the power
failure indicator turns off. If you wish to cancel
the program, simply press the RESET key. This
function is not active while a single cycle is
running.
End of Program
When a program has completed, the message
PLEASE WAIT is displayed and the buzzer
sounds for a minimum of 90 seconds. Then, if
the water level is lower than 3cm and the
temperature is lower than 40C, the door may
be opened. The buzzer can be silenced by
pressing the RESET key. If the temperature or
water level are too high, the display shows the
offending value and the door cannot be
opened.
PRWH 1 EXECUT.?
Summary of Contents for FM7
Page 2: ......