A1 B
ASIC - c
onnection diagr
am with REL-4
A1
ELECTRO-MECHANICAL SECURITY LOCK
The REL-4 interface is available to turn the
signals coming from the lock into potential
free contacts.
It also facilitates the
connection of the access control.
In order to guarantee the correct
functioning of the lock, 24Vdc (+/- 5%) /
2.5A has to reach the lock.
We suggest
using our PS24D52 power supply and
BB25LSZH cable (2x1.5mm² + 5x0.22mm²).
The maximum distance between the power
supply and the lock is 25m.