Server Properties Configuration
38
Chapter 5
Manual Documentation Number: ESP901-902_5012m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 –
www.bb-elec.com
B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 –
www.bb-europe.com
RS-485
– When this mode is selected and the server updated, the
selected serial port will become an RS-485 serial port on the
server.
Connection At
When the
Connection Mode
field is set to
Client
or
Client (no
heartbeat)
, this field becomes active, allowing the ESP901/902 (acting
as a client) to connect to the server either on
Power up
or on
Data
Arrival
(first character arriving).
Max Connection
This field allows the user to configure the
Serial Server
to have up to
eight TCP connections.
Remote IP Address
This is a security feature activated by entering the IP address of the
desired client. The
Serial Server
will only communicate with the listed
IP address and all other requests for connection will be filtered out. The
Serial Server
must be set up as a
TCP
or
UDP Server
to use this
feature. The default setting is
255.255.255.255
.
If
Paired Mode
is not being used, do not change this setting until the
application has been tested and is communicating properly. Then
activate the address filtering feature.
N
N
o
o
t
t
e
e
:
:
Refer to Chapter 1 Paired Mode
Update/Save
Server properties must be updated separately for each serial port.
Updating varies slightly depending on which of the four configuration
user interfaces are used.
Updating the Server Properties in ESP Manager
From the
Server Properties
screen, click the
Update
button to store
the configuration settings for the currently selected port. The vcomui
dialogue box will appear indicating you must restart the device before
the new settings will take effect. Click
Yes
.