Port Status 

This field indicates whether a serial port is connected via the 

Serial 

Server

 to a virtual COM port of a device on the network. 

TCP/UDP Port  

This sets the port number for connection. The default port number for 
the 

ESP901

 is 

4000

. The default port numbers for the 

ESP902

 are 

4000

 

and 

4001 

for serial ports 1 and 2 respectively. 

In all modes of operation, 

Direct IP

 or 

Virtual COM

, the port number 

set in the 

Server Properties

 menu must match the 

Virtual COM

 or 

socket software port settings.  

N

N

o

o

t

t

e

e

:

:

 

 

 

Example: The Virtual COM default setting is TCP/UDP Port 4000. If 

the port # property is changed to 4001, the virtual COM port will have 

to be changed to 4001. The hardware settings can be changed from 

the ESP Manager or Console Configuration Menu. The Virtual COM 

port setting also can be changed within the Device Manager of the 
computer on which it is installed.  

Serial Port Mode 

Serial Port Mode

 allows configuration of the serial server for the 

following modes of operation: 

 

Console

 – When this mode is selected and the server is updated, a 

PC running a communications program such as HyperTerminal can 
communicate with the 

Serial Server

 via the 

Console Mode

 serial 

port (the serial Port on ESP901 or Port 1 on ESP902), displaying 
the 

Server Properties

 screen and allowing configuration of the 

server and its ports. 

 

Upgrade

 – When this mode is selected and the server is updated, 

firmware can be uploaded into the 

Serial Server

 via the 

Console 

Mode

 serial port or a virtual COM port mapped to the number of 

the 

Console Mode

 serial port. 

 

Default

 – When this mode is selected and the server is updated, it 

will revert the server to its default configuration. 

 

RS-232

 – When this mode is selected and the server updated, the 

selected serial port will become an RS-232 serial port on the 
server.  

 

RS-422

 – When this mode is selected and the server updated, the 

selected serial port will become an RS-422 serial port on the 
server.  

Server Properties Configuration

 

38 

Chapter 5 

Manual Documentation Number: ESP901-902_4105m 

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – 

www.bb-elec.com

 

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – 

www.bb-europe.com

 

 

RS-485

 – When this mode is selected and the server updated, the 

selected serial port will become an RS-485 serial port on the 
server.  

Connection At 

When the 

Connection Mode

 field is set to 

Client

 or 

Client (no 

heartbeat)

, this field becomes active, allowing the ESP901/902 (acting 

as a client) to connect to the server either on 

Power up

 or on 

Data 

Arrival

 (first character arriving). 

Max Connection 

This field allows the user to configure the 

Serial Server

 to have up to 

eight TCP connections. 

Remote IP Address  

This is a security feature activated by entering the IP address of the 
desired client. The 

Serial Server

 will only communicate with the listed 

IP address and all other requests for connection will be filtered out. The 

Serial Server

 must be set up as a 

TCP

 or 

UDP Server

 to use this 

feature. The default setting is 

255.255.255.255

.  

If 

Paired Mode

 is not being used, do not change this setting until the 

application has been tested and is communicating properly. Then 
activate the address filtering feature.  

N

N

o

o

t

t

e

e

:

:

 

 

 

Refer to Chapter 1 Paired Mode  

Update/Save 

Server properties must be updated separately for each serial port. 
Updating varies slightly depending on which of the four configuration 
user interfaces are used.  

Updating the Server Properties in ESP Manager 

From the 

Server Properties

 screen, click the 

Update 

button to store 

the configuration settings for the currently selected port. The vcomui 
dialogue box will appear indicating you must restart the device before 
the new settings will take effect. Click 

Yes

.  

Summary of Contents for RS-485

Page 1: ...s s M Mo od de el ls s E ES SP P9 90 01 1 E ES SP P9 90 01 1E E E ES SP P9 90 02 2 E ES SP P9 90 02 2E E International Headquarters B B Electronics Mfg Co Inc 707 Dayton Road Ottawa IL 61350 USA Phone...

Page 2: ...ange without notice and does not represent a commitment on the part of B B Electronics B B Electronics shall not be liable for incidental or consequential damages resulting from the furnishing perform...

Page 3: ...17 Automatic Installation 17 Manual Installation 17 Updating an Existing Installation 19 Opening the ESP Manager 20 ii Table of Contents Manual Documentation Number ESP901 902_4105m B B Electronics M...

Page 4: ...GURATION USING TELNET 63 Navigating the Configuration Menu 64 CHAPTER 12 ESP901 AND ESP902 TECHNICAL DATA 67 APPENDIX A RS 232 CONNECTIONS 71 SERIAL SERVER DB 9 PIN OUTS IN RS 232 MODE 71 RS 232 Strai...

Page 5: ...ort 2 is RS 232 only 10 100 Mbps Ethernet with Auto Selection LAN and WAN Communications TCP or UDP Client or Server operation configurable Software Support Windows 98 ME 2000 XP or NT 4 0 Firmware Up...

Page 6: ...network to the Serial Server which converts the IP packet back to serial data and sends the data out a serial port located on the Serial Server To use this mode the Serial Server must be set to eithe...

Page 7: ...ox 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Pk Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Softwar...

Page 8: ...and map it to an unused COM port e g Port 15 Configure it for TCP protocol and the appropriate IP address determined in the last section Figure 4 Configuring the Virtual COM Port Check Communications...

Page 9: ...m B B Electronics Ltd Westlink Commercial Pk Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Indicator Lights Light Indication Power Red power is applied Link Yellow 10Bas...

Page 10: ...ON position 2 With any DIP switch in the OFF position set the Server Properties Console Mode field to Console and Update Save the configuration Making Hardware Connections 12 Chapter 2 Manual Documen...

Page 11: ...re single ended and referenced to Ground To use handshaking Flow Control must be set to RTS CTS during Configuration N No ot te e Refer to Appendix A for RS 232 connection pin outs Making Hardware Con...

Page 12: ...it Data TXD Out TXDB Data B 4 Data Terminal Ready DTR Out TXDA Data A 5 Signal Ground GND GND GND 6 Data Set Ready DSR In CTSA 7 Request To Send RTS Out CTSB 8 Clear To Send CTS In RTSB 9 Ring Indicat...

Page 13: ...tion Step 1a Inserting the VLINX CD in the CD ROM should automatically launch the Install Shield Wizard Manual Installation Step 1b To manually start the software installation from the Windows Desktop...

Page 14: ...Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Pk Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 ww...

Page 15: ...t port Set all the DIP switches on the Serial Server to the OFF position Figure 19 Ethernet Connection via a LAN Using ESP Manager 22 Chapter 4 Manual Documentation Number ESP901 902_4105m B B Electro...

Page 16: ...guration information that will be displayed in the Server Properties window Uninstall Virtual COM Allows virtual COM ports to be uninstalled from the ESP Manager window Monitor Port Status Brings up a...

Page 17: ...M port condition o Not Connected is shown when a program does not have the port Open o Connected is shown when that mapped port is Open for use Virtual COM List COM Name Displays the number of the COM...

Page 18: ...urrently selected server Step 6 To open the Server Properties window highlight the Serial Server in the Serial Server List window double click to open The Server Properties window is used to configure...

Page 19: ...rch Dialogue Box While the Serial Server is searching for all reachable servers the following dialogue box appears Figure 28 The Search VLINX ESP Dialogue Box After that port has been updated you may...

Page 20: ...433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Pk Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Description of the Server Properties Figure 30 ESP Mana...

Page 21: ...At run prompt enter CMD In the DOS window enter Ping xxx xxx xxx xxx IP address for the server to be confirmed The command will return the Ping results indicating 4 replies Figure 31 Pinging using the...

Page 22: ...om communications are ideal for 5 seconds the Serial Server will reset and make itself available for another client connection TCP Alive Timeout The Serial Server monitors TCP activity If TCP activity...

Page 23: ...e server to its default configuration RS 232 When this mode is selected and the server updated the selected serial port will become an RS 232 serial port on the server RS 422 When this mode is selecte...

Page 24: ...Electronics Ltd Westlink Commercial Pk Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com After that port has been updated you may want to re enter Server Properties to veri...

Page 25: ...Telnet These are located at the bottom of all three Web Server pages If a field is changed you must click Save before leaving that page or the changes will be ignored Figure 37 The Web Server Page N...

Page 26: ...tions which allows the software to open a connection with the serial port located anywhere on the LAN WAN When using the virtual COM port the Serial Server is configured as a TCP or UDP Server Virtual...

Page 27: ...one RTS CTS can be selected if used by the application program and serial hardware The Serial Server must be set to match Installing Virtual COM Port 46 Chapter 6 Manual Documentation Number ESP901 90...

Page 28: ...Click the Configuration or Port Settings tab This screen allows the settings to be changed if necessary Click Cancel to keep the existing settings Step 5 Click OK to change the settings Use Refresh i...

Page 29: ...1 From the Windows Desktop click Start Programs B B Electronics VLINX ESP Servers VLINX ESP Manager Step 2 In the ESP Manager window click the Virtual COM List tab Highlight the mapped COM port number...

Page 30: ...o expand Figure 47 The Device Manager Window Step 4 Highlight ESP COM to be removed and click the Action tab at the top of window then clickUninstall A confirm Device Removal window will appear Removi...

Page 31: ...ing a direct connection to upload the firmware to the Serial Server set the baud rate to 115200 for the fastest possible upload Step 3 Set the Serial Port field to upgrade and click the Update button...

Page 32: ...via an RS 232 crossover cable Step 3 In the HyperTerminal Port Settings window set o Baud rate 9600 o Data bits 8 o Parity None o Stop bits 1 o Flow control None Click OK Step 4 Ensure all the DIP sw...

Page 33: ...e Configuration The restart message will appear Step 6 Select Yes to save changes This is necessary to write the settings to the server Using a Password If a password is used it must be entered before...

Page 34: ...plorer type the IP Address of the Serial Server into the address field near the top of the window and press the Enter key The following window will appear Figure 52 The Web Server Page Using the Web S...

Page 35: ...s to the Serial Server Settings for each Port must be saved separately N No ot te e If new property settings are not saved before leaving this page they will not take effect Return to the main Server...

Page 36: ...Telnet and the IP address of the Serial Server to be configured then click OK Figure 55 The Run dialogue box N No ot te e The Serial Server must be in RS 232 RS 422 or RS 485 mode before you can Telne...

Page 37: ...c 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Pk Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www b...

Page 38: ...e 9 pin D type male DB 9M DTE software selectable as RS 232 422 or 485 ESP902 Two 9 pin D type male DB 9M DTE Port 1 software selectable as RS 232 422 or 485 Port 2 RS232 only DC Power Ultra miniature...

Page 39: ...ort 1 Baud Rate 9600 Data Stop 8 1 Parity None Flow Control None TCP UDP Protocol ESP901 serial port TCP ESP902 Ports 1 2 TCP Serial timeout 0 seconds TCP alive timeout 0 minutes Connection Mode Serve...

Page 40: ...k Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com RS 232 Straight through Cable Connections In the RS 232 mode the Serial Server s ports are configured as DTEs like a comp...

Page 41: ...Connections RS 232 Connections 74 Appendix A Manual Documentation Number ESP901 902_4105m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb...

Page 42: ...lines are outputs and RXD lines are inputs Connect the Serial Server TXDB line to the RXDB line of the serial device and the Serial Server TXDA to the RXDA of the serial device If Flow Control is set...

Page 43: ...Loopback Connections for RS 422 The RS 485 Connections are half duplex either Receive or Transmit so another half duplex device must be used to check operation Figure 69 RS 422 Connection with No Flo...

Page 44: ...standard which defines the Data B line as positive relative to Data A during a Mark state before enabling the transmitter and after transmitting before tri stating If an RS 485 device does not respond...

Page 45: ...used Blue 4 5 Not used White Blue 5 6 RX Orange 6 7 Not used White Brown 7 8 Not used Brown 8 Figure 72 Pin out for a Standard Ethernet Cable Network Connections 82 Appendix D Manual Documentation Num...

Page 46: ...il orders bb elec com Fax 815 433 5109 Technical Support e mail support bb elec com Fax 815 433 5104 European Headquarters B B Electronics Ltd Westlink Commercial Park Oranmore Co Galway Ireland Phone...

Reviews: