background image

8

 

Remote Unit 

This option allows the user to enable Remote Unit on the module.  The Remote Unit 
feature is designed to work only as the remote module of the Local/Remote pair

 

in 

the required Master/Slave configuration.  With Remote Unit enabled, the user can 

easily perform the following: 

 

Test the line integrity of the remote copper port. 

 

Use the Local unit to configure all SNMP-configurable features for both units. 

 

Use the Local unit to download firmware for both units. 

Refer to the 

Module LED Functions

 section for more information. 

By default this feature is set to 

Disabled

This feature can only be selected by setting the DIP Switches manually.  

Loopback Testing 

The iMcV-DS3/E3/STS includes two loopback test modes: Coax Loopback and Fiber 

Loopback.   
The following illustrations show the path that a signal takes in each of the loopback 
test modes. 

 

Each loopback performs the following: 

 

Redirects the incoming signal back out to the origin while continuing to transmit 
downstream. 

 

Blocks downstream data from arriving on the looped data line. 

9

 

Loopback testing is useful for troubleshooting problems with network connections 

should they occur.  Looping received data back onto the transmit path helps 
determine whether a connection is still valid.  Remote loopback tests isolate problems 

on the coax run between an iMcV-DS3/E3/STS module and the connected device, 

while local loopback tests can isolate problems on the fiber connected to the module. 
The following illustrations show a typical progression of loopback tests (i.e. starting by 
checking the coax segment at the local side, then the coax segment at the remote 

side, etc). 

 

 

 

 

 

Pseudorandom Bit Sequence (PRBS) Testing 

To test using Pseudorandom Bit Sequence, configure the iMcV-DS3/E3/STS modules 

for No Loopback, then configure the Transmit Data Source to “Transmit 

Summary of Contents for iMcV-DS3

Page 1: ...ase price based on a depreciated value Products of other manufacturers sold by B B Electronics are not subject to any warranty or indemnity offered by B B Electronics but may be subject to the warrant...

Page 2: ...preted by the receive fiber of another iMcV DS3 E3 STS The single strand versions must have opposite transmit and receive wavelengths for example one that transmits at 1310 nm must be paired with anot...

Page 3: ...designed specifically for the B B Electronics iMcV family of modules It features a GUI and gives network managers the ability to monitor and control the manageable B B Electronics products iView is av...

Page 4: ...oftware iView2 when the iMcV DS3 E3 STS module is installed in a managed chassis Jitter Attenuation This switch selects the jitter attenuation location on the coax transceiver The jitter attenuation c...

Page 5: ...ransmit mode used by the iMcV DS3 E3 STS module The transmit modes that can be selected include the following Standard data Unframed All Ones diagnostic Alternating Ones and Zeros diagnostic Pseudoran...

Page 6: ...al takes in each of the loopback test modes Each loopback performs the following Redirects the incoming signal back out to the origin while continuing to transmit downstream Blocks downstream data fro...

Page 7: ...it Data Source is set to Pseudo random Bit Sequence this LED will glow yellow when iMcV DS3 E3 STS receives a Pseudorandom Bit Sequence with errors The LED stays off when the converter receives a Pseu...

Page 8: ...cable then follow these steps to test 1 Connect the media converter to the BNC device with a coax cable 2 Loop a single strand of fiber from the transmit port to the receive port of your media conver...

Page 9: ...les 1 Use fiber patch cords or connectors if you terminate your own fiber only from a reputable supplier low quality components can cause many hard to diagnose problems in an installation 2 Dust caps...

Page 10: ...mage Do not handle these components directly unless you are a qualified service technician and use tools and techniques that conform to accepted industry practices 17 Safety Certifications UL CUL List...

Page 11: ...land Phone 353 91 792444 Fax 353 91 79244S5 Email techSupport bb elec com Website www bb elec com The information in this document is subject to change without notice B B Electronics assumes no respon...

Reviews: