Manual Documentation Number: EIRM-EXTEND-8-1
m
151
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
802.1x
Radius Configuration, Port Authentication
Radius Configuration
Radius Status:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use
dot1x system-auth-ctrl
command to globally enable authentication.
Use
no dot1x system-auth-ctrl
command to globally disable
authentication.
3.
Command Syntax:
(no) dot1x system-auth-ctrl
4.
Example:
The following example globally enables authentication:
switch_a(config)#dot1x system-auth-ctrl
switch_a(config)#
Radius Server IP:
Radius Server Port:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use this command to specify the IP address of the remote radius server host
and assign authentication and accounting destination port number.
3.
Command Syntax:
(no) radius-server host IP-ADDRESS auth-port PORT
IP-ADDRESS A.B.C.D specifies the IP address of the radius server host.
PORT specifies the UDP destination port for authentication requests. The
host is not used for authentication if set to 0.
4.
Example: