Manual Documentation Number: EIRM-EXTEND-8-1
m
111
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Switching
Bridging, Static MAC Entry, Port Mirroring
Bridging
Aging Time (seconds):
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use this command to specify an ageing-out time for a learned MAC
address. The learned MAC address will persist till this specified time.
3.
Command Syntax:
Bridge GROUP ageing-time AGEINGTIME
no bridge GROUP ageing-time
Group = <1-1> The ID of the bridge-group that this ageing time is for.
AGEINGTIME = <10-1000000> The number of seconds of persistence.
4.
Example:
The following example sets the new AGEINGTIME (
1000
) to bridge
GROUP (
1
):
switch_a(config)#bridge 1 ageing-time 1000
switch_a(config)#
Threshold level (0-100):
1.
Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The
switch_a(config-if)#
prompt will show on the screen.
switch_a(config)#interface fe1
switch_a(config-if)#
2.
Usage:
Use
storm-control level
command to specify the rising threshold level for
broadcasting, multicast, or destination lookup failure traffic. The storm
control action occurs when traffic utilization reaches this level.
3.
Command Syntax:
storm-control level LEVEL