Factory Default interface 

 

 

 

Save Configuration 

 

Save configuration changes click 

Save Flash

   

 

 

Save Configuration interface 

 

 

System Reboot   

 

Reboot the switch click 

Reboot

   

 

 

System Reboot interface 

Summary of Contents for Elinx EIR510-2MC-T

Page 1: ...8m 707 Dayton Road P O Box 1040 Ottawa IL 61350 USA Phone 815 433 5100 General Fax 815 433 5105 Phone 815 433 5100 General Fax 815 433 5105 Website www bb elec com Sales e mail orders bb elec com Fax 815 433 5109 Technical Support e mail support bb elec com Fax 815 433 5104 European Headquarters B B Electronics Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Fax 353 91 7924...

Page 2: ...x 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Ten Port Managed Industrial Ethernet Switches User Manual ...

Page 3: ...mful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the...

Page 4: ... Fax 353 91 792445 www bb europe com Content Introduction 1 Features 1 Package Contents 3 Hardware Description 4 Physical Dimension W x D x H 4 Front Panel 4 Bottom View 5 LED Indicators 6 Ports 7 Cabling 9 Wiring the Power Inputs 10 Wiring the Fault Alarm Contact 11 Mounting Installation 12 DIN Rail Mounting 12 Panel Mounting 14 Hardware Installation 15 Installation Steps 15 Network Application 1...

Page 5: ...Ring Application 17 Dual Homing Application 18 Console Management 19 Connecting to the Console Port 19 Login in the Console Interface 19 CLI Management 20 Commands Level 21 Commands Set List 22 Web Based Management 46 About Web based Management 46 Preparing for Web Management 46 System Login 47 System Information 48 IP Configuration 48 DHCP Server System configuration 49 DHCP Client System Configu...

Page 6: ...ion 52 TFTP Backup Configuration 52 System Event Log Syslog Configuration 53 System Event Log SMTP Configuration 54 System Event Log Event Configuration 55 Fault Relay Alarm 56 SNTP Configuration 57 IP Security 60 User Authentication 61 Port Statistics 61 Port Control 62 Port Trunk 63 Aggregator setting 63 Aggregator Information 65 State Activity 65 Port Mirroring 66 Rate Limiting 67 VLAN configur...

Page 7: ...Spanning Tree 73 RSTP System Configuration 73 RSTP Port Configuration 75 SNMP Configuration 76 System Configuration 76 Trap Configuration 77 SNMPV3 Configuration 78 QoS Configuration 81 QoS Policy and Priority Type 81 Port Base Priority 83 COS Configuration 83 TOS Configuration 83 IGMP Configuration 84 X Ring 85 802 1X Radius Configuration 87 MAC Address Table 90 Factory Default 92 Save Configurat...

Page 8: ... Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Technical Specification 95 ...

Page 9: ...switch can be easily managed through a Web GUI The fiber ports extend the connection distance increasing network elasticity and performance Features System Interface Performance RJ 45 ports with Auto MDI MDI X Store and Forward Switching Architecture Back plane Switching Fabric 2Gbps 1Mbits Packet Buffer 8K MAC Address Table Power Supply Wide range Redundant Power Design Reverse Polarity Protectio...

Page 10: ...or Multi Media Application Case Installation IP 30 Protection DIN Rail and Panel Mount Design Spanning Tree IEEE802 1d Spanning Tree IEEE802 1w Rapid Spanning Tree X ring X ring Dual Homing and Couple Ring Topology Redundant backup feature with recovery time below 300ms Bandwidth Control Ingress Packet Filter and Egress Rate Limit Broadcast Multicast Packet Filter Control System Event Log System L...

Page 11: ...com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Package Contents One Managed industrial switch One CD ROM containing a user manual RS 232 RJ 45 cable 2 panel mount plates with 6 screws One DIN Rail Clip attached on the switch If any items are missing contact B B Electronics for a replacement ...

Page 12: ...L 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Hardware Description Physical Dimension W x D x H 2 9 x 4 2 x 6 4 in 7 4 x 10 7 x 16 3 cm Front Panel Front Panel of the industrial switch ...

Page 13: ...fg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Bottom View Bottom Panel of the industrial switch ...

Page 14: ...available Off Power source 1 is unavailable PWR2 Green Power source 2 is available Off Power source 2 is unavailable Fault Orange Power or port failure See alarm setting for operational details Off Normal Operation R M Green The switch is the master of an X Ring group Off The switch is not the master of an X Ring group LNK ACT Green Fiber port linked Blinks Fiber port transmitting or receiving Off...

Page 15: ...al Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Ports RJ 45 ports There are 8x 10 100Mbps auto sensing ports with MDI MDIX The switch can connect to another switch or workstation without changing between straight through or crossover cabling RJ 45 Pin Assignments Pin Number Assignment 1 Tx 2 Tx 3 Rx 6 Rx Straight Through Cable Schematic Cross Over Cable Schemat...

Page 16: ...link Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Fiber Port There are two 100Base FX ports The fiber port is SC or ST type connectors in multi mode 2Km or single mode 30Km Connect the fiber ports as shown below Transmit to distant end receive and vice versa ATTENTION This is a Class 1 Laser LED product Do not stare into the Laser LED Beam ...

Page 17: ...92444 Fax 353 91 792445 www bb europe com Cabling Use Category 5 cabling for RJ 45 port connection The cable between the switch and the network device switch hub workstation etc must be less than 328 feet 100 meters long Single mode fiber ports must use 9 125 um single mode fiber cable The cable length can be up to 30 Kilometers Multi mode fiber ports must use 50 or 62 5 125 um multi mode fiber ca...

Page 18: ... 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Wiring the Power Inputs NOTE Use 12 to 24 AWG wire V V V V 1 Insert the positive and negative wires into the V and V contacts on the terminal block connector 2 To tighten the wire clamp screws ...

Page 19: ...ctronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Wiring the Fault Alarm Contact NOTE Use 12 to 24 AWG wire NOTE Relay contacts are normally open NOTE The Relay Alarm also requires software configuration Refer to the Web Based Management Fault Relay Alarm Section Insert the wires into the fault alarm contact 1A 24V ...

Page 20: ...tawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Mounting Installation DIN Rail Mounting 1 Use the screws to attach the DIN Rail to the switch Rear Panel of the switch DIN Rail ...

Page 21: ... 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 1 Insert the top of DIN Rail into the track 2 Lightly push the DIN Rail into the track 3 Ensure the DIN Rail is tightly on the track 4 To remove the industrial switch from the track reverse steps above ...

Page 22: ... elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Panel Mounting 1 Remove the DIN Rail Clip 2 Place the panel mount plate on the rear panel of the industrial switch 3 Use the screws to attach the panel mount plate 4 Use the hook holes at the corners to attach the switch to the panel ...

Page 23: ...5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Hardware Installation Installation Steps 1 Unpack the switch 2 Attach the switch to the DIN Rail or panel 3 Apply power to the switch 4 Connect the switch to the network devices ...

Page 24: ...ay Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Network Application X Ring Application This switch incorporates the X Ring Protocol to ensure network reliability and system restoration within 300 ms in the event of a connection failure The X Ring algorithm is similar to the spanning tree protocol STP algorithm but it has faster recovery time The following figure below is an example...

Page 25: ...cs Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Coupling Ring Application If the network has more than one X Ring group the coupling ring function is used to connect them and add redundancy This ensures that transmissions between the two ring groups will not fail The figure below is an example of the coupling ring application ...

Page 26: ...Ph 353 91 792444 Fax 353 91 792445 www bb europe com Dual Homing Application The Dual Homing function is used to prevent a connection loss between the X Ring group and the upper level core switch Assign a port in each X ring group to be the Dual Homing ports The Dual Homing function can only be used when the X Ring function is active Each X Ring group can have one Dual Homing port Note The upper l...

Page 27: ...e DB9 end to a PC or terminal and the RJ 45 end to the console port on the switch The PC must have support a terminal emulation program Login in the Console Interface When the connection between Switch and PC is ready turn on the PC run a terminal emulation program or Hyper Terminal and configure the following communication parameters Baud Rate 9600 bps Data Bits 8 Parity none Stop Bit 1 Flow cont...

Page 28: ...nd Ph 353 91 792444 Fax 353 91 792445 www bb europe com The settings of communication parameters After entering the parameters click OK When the blank screen shows up press Enter on the PC keyboard A login screen will be displayed Enter root for the User name and Password Console login interface CLI Management After you login to the system you will see a command prompt To enter CLI management inte...

Page 29: ...mmands Level Modes Access Method Prompt Exit Method About This Mode1 User EXEC Begin a session with your switch switch Enter logout or quit The user commands available at the user level are a subset of those available at the privileged level Use this mode to Perform basic tests Displays system information Privileged EXEC Enter the enable command while in user EXEC mode switch Enter disable to exit...

Page 30: ...e to configure parameters that apply to your switch as a whole VLAN database Enter the vlan database command while in privileged EXEC mode switch vlan To exit to user EXEC mode enter exit Use this mode to configure VLAN specific parameters Interface configuration Enter the interface command with a specific interface while in global configuration mode switch config if To exit to global configuratio...

Page 31: ... location System Location G Set switch system location string switch config system location xxx system description System Description G Set switch system description string switch config system description xxx system contact System Contact G Set switch system contact window string switch config system contact xxx show system info E Show system information switch show system info ip address Ip addr...

Page 32: ...high IP address for IP pool switch config dhcpserver highip 192 168 1 200 dhcpserver subnetmask Subnet mask G Configure subnet mask for DHCP clients switch config dhcpserver subnetmask 255 255 255 0 dhcpserver gateway Gateway G Configure gateway for DHCP clients switch config dhcpserver gateway 192 168 1 254 dhcpserver dnsip DNS IP G Configure DNS IP for DHCP clients switch config dhcpserver dnsip...

Page 33: ...how security P Show the information of IP security switch show security no security G Disable IP security function switch config no security no security http G Disable IP security of HTTP server switch config no security http no security telnet G Disable IP security of telnet server switch config no security telnet Port Commands Set Commands Level Description Example interface fastEthernet Portid ...

Page 34: ...o accept all frame switch config interface fastEthernet 2 switch config if bandwidth type all bandwidth type broadcast multicast floo ded unicast I Set interface ingress limit frame type to accept broadcast multicast and flooded unicast frame switch config interface fastEthernet 2 switch config if bandwidth type broadcast multicast flooded uni cast bandwidth type broadcast multicast I Set interfac...

Page 35: ... Show interfaces bandwidth control switch config interface fastEthernet 2 switch config if show bandwidth state Enable Disable I Use the state interface configuration command to specify the state mode of operation for Ethernet ports Use the disable form of this command to disable the port switch config interface fastEthernet 2 config if state Disable show interface configuration I show interface c...

Page 36: ...ID Port Numbers G Set activity port switch config aggregator activityport 2 aggregator group GroupID Port list lacp workp Workport G Assign a trunk group with LACP active GroupID 1 3 Port list Member port list This parameter could be a port range ex 1 4 or a port list separate by a comma ex 2 3 6 Workport The amount of work ports this value could not be less than zero or be large than the amount o...

Page 37: ...nction of trunk group switch config no aggreator lacp 1 no aggregator group GroupID G Remove a trunk group switch config no aggreator group 2 VLAN Commands Set Commands Level Description Example vlan database P Enter VLAN configure mode switch vlan database Vlanmode portbase 802 1q gvrp V To set switch VLAN mode switch vlan vlanmode portbase or switch vlan vlanmode 802 1q or switch vlan vlanmode g...

Page 38: ...ag 33 vlan 8021q port PortNumber trunk link tag TaggedVID List V Assign a trunk link for VLAN by port if the port belongs to a trunk group this command can t be applied switch vlan vlan 8021q port 3 trunk link tag 2 3 6 99 or switch vlan vlan 8021q port 3 trunk link tag 3 20 vlan 8021q port PortNumber hybrid link untag UntaggedVID tag TaggedVID List V Assign a hybrid link for VLAN by port if the p...

Page 39: ... 23 no vlan group GroupID V Delete port base group ID switch vlan no vlan group 2 Spanning Tree Commands Set Commands Level Description Example spanning tree enable G Enable spanning tree switch config spanning tree enable spanning tree priority 0 61440 G Configure spanning tree priority parameter switch config spanning tree priority 32767 spanning tree max age seconds G Use the spanning tree max ...

Page 40: ...g tree hello time 3 spanning tree forward time seconds G Use the spanning tree forward time global configuration command to set the forwarding time for the specified spanning tree instances The forwarding time determines how long each of the listening and learning states last before the port begins forwarding switch config spanning tree forward time 20 stp path cost 1 200000000 I Use the spanning ...

Page 41: ... Admin P2P of STP priority on this interface switch config interface fastEthernet 2 switch config if stp admin p2p Auto stp admin edge True False I Admin Edge of STP priority on this interface switch config interface fastEthernet 2 switch config if stp admin edge True stp admin non stp True False I Admin NonSTP of STP priority on this interface switch config interface fastEthernet 2 switch config ...

Page 42: ...rity lowest low mid dle high G Configure TOS Priority switch config qos priority tos 3 high show qos P Displays the information of QoS configuration Switch show qos no qos G Disable QoS function switch config no qos IGMP Commands Set Commands Level Description Example igmp enable G Enable IGMP snooping function switch config igmp enable Igmp query auto G Set IGMP query to auto mode switch config I...

Page 43: ...w mac address table static P Show static MAC address table switch show mac address table static show mac address table filter P Show filter MAC address table switch show mac address table filter no mac address table static hwaddr MAC I Remove an entry of MAC address table of interface static switch config interface fastEthernet 2 switch config if no mac address table static hwaddr 000012345678 no ...

Page 44: ...ng trap version v1 v2c G Configure SNMP server host information and community string switch config snmp server host 192 168 1 50 community public trap version v1 remove Switch config no snmp server host 192 168 1 50 snmpv3 context name Context Name G Configure the context name switch config snmpv3 context name Test snmpv3 user User Name group Group Name password Authentication Password Privacy Pas...

Page 45: ...1 3 6 1 show snmp P Show SNMP configuration switch show snmp no snmp community strings Community G Remove the specified community switch config no snmp community strings public no snmp server host Host address G Remove the SNMP server host switch config no snmp server 192 168 1 50 no snmpv3 user User Name G Remove specified user of SNMPv3 agent switch config no snmpv3 user Test no snmpv3 access co...

Page 46: ...or function switch config monitor rx monitor tx G Set TX destination port of monitor function switch config monitor tx show monitor P Show port monitor information switch show monitor monitor RX TX Both I Configure source port of monitor function switch config interface fastEthernet 2 switch config if monitor RX show monitor I Show port monitor information switch config interface fastEthernet 2 sw...

Page 47: ...021x system accountport port ID G Use the 802 1x system account port global configuration command to change the accounting port switch config 8021x system accountport 1816 8021x system sharekey ID G Use the 802 1x system share key global configuration command to change the shared key value switch config 8021x system sharekey 123456 8021x system nasid words G Use the 802 1x system nasid global conf...

Page 48: ...ommand to set the server timeout switch config 8021x misc servertimeout 20 8021x misc maxrequest number G Use the 802 1x misc max request global configuration command to set the MAX requests switch config 8021x misc maxrequest 3 8021x misc reauthperiod sec G Use the 802 1x misc reauth period global configuration command to set the reauth period switch config 8021x misc reauthperiod 3000 8021x port...

Page 49: ...ore flash restore_cfg upgrade flash upgrade_fw G Upgrade firmware by TFTP and need to specify the IP of TFTP server and the file name of image switch config upgrade lash upgrade_fw SystemLog SMTP and Event Commands Set Commands Level Description Example systemlog ip IP address G Set System log server IP address switch config systemlog ip 192 168 1 100 systemlog mode client server both G Specified ...

Page 50: ...itch config event device cold start both event authentication failure Systemlog SMTP Both G Set Authentication failure event type switch config event authentication failure both event X ring topology change Systemlog SMTP Both G Set X ring topology changed event type switch config event X ring topology change both event systemlog Link UP Link Down Bot h I Set port event for system log switch confi...

Page 51: ...nformation switch show systemlog SNTP Commands Set Commands Level Description Example sntp enable G Enable SNTP function switch config sntp enable sntp daylight G Enable daylight saving time if SNTP function is inactive this command can t be applied switch config sntp daylight sntp daylight period Start time End time G Set period of daylight saving time if SNTP function is inactive this command ca...

Page 52: ...p no sntp daylight G Disable daylight saving time switch config no sntp daylight X ring Commands Set Commands Level Description Example Xring enable G Enable X ring switch config Xring enable Xring master G Enable ring master switch config Xring master Xring couplering G Enable couple ring switch config Xring couplering Xring dualhoming G Enable dual homing switch config Xring dualhoming Xring rin...

Page 53: ...tronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com no Xring G Disable X ring switch config no X ring no Xring master G Disable ring master switch config no Xring master no Xring couplering G Disable couple ring switch config no Xring couplering no Xring dualhoming G Disable dual homing switch config no Xring dualhoming ...

Page 54: ...nagement features and allows the switch to be configured from anywhere on the network The web site is designed for Internet Explorer 6 0 and uses Java Applets to reduce bandwidth consumption enhance access speed and present an intuitive user interface Preparing for Web Management Before using web management install the industrial switch on the network and verify that a PC on the local network can ...

Page 55: ... B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com System Login 1 Launch Internet Explorer on the PC 2 Enter http the IP address of the switch and then Press Enter 3 The login screen will appear 4 Enter user name and password The default user name and password are root 5 Press Enter or OK Login screen ...

Page 56: ...version MAC Address Displays the unique hardware address assigned by manufacturer default IP Configuration Configure the IP Settings and DHCP client function DHCP Client Used to enable or disable the DHCP client function When enabled the switch s IP address is assigned by the network DHCP server The default IP address will be replace by the DHCP server assigned IP address After clicking the Apply ...

Page 57: ...tem configuration The switch can function as a DHCP server DHCP Server Enable or Disable the DHCP Server function Low IP Address the dynamic IP assign range Low IP address is the beginning of the dynamic IP assignment range High IP Address the dynamic IP assign range High IP address is the end of the dynamic IP assignment range Subnet Mask The subnet mask Gateway The network gateway DNS Network Do...

Page 58: ...nd Ph 353 91 792444 Fax 353 91 792445 www bb europe com DHCP Server Configuration interface DHCP Client System Configuration DHCP client information is displayed DHCP Client Entries interface DHCP Server Port and IP Bindings You can assign a specific IP address that is in the dynamic IP assignment range to the specific port When the device is connected to the port and asks for an assignment the sy...

Page 59: ...ore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Port and IP Bindings interface TFTP Update Firmware Provides the ability to update the switch s firmware Before updating ensure you the TFTP server is ready and the firmware image is on the TFTP server 1 TFTP Server IP Address Enter the TFTP server IP 2 Firmware File Name Enter the name of firmware image 3 Click Apply Update F...

Page 60: ...europe com TFTP Restore Configuration If the EEPROM image is stored on the TFTP server you can restore it to flash memory 1 TFTP Server IP Address Enter the TFTP server IP 2 Restore File Name Enter the restore file name 3 Click Apply Restore Configuration interface TFTP Backup Configuration You can save current EEPROM image to the TFTP server 1 TFTP Server IP Address Enter the TFTP server IP 2 Bac...

Page 61: ... Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com System Event Log Syslog Configuration 1 Syslog Client Mode select the system log mode client only server only or both S C 2 System Log Server IP Address Assign the system log server IP 3 Click Reload to refresh the event log 4 Click Clear to clear all current event log 5 After configuring Click Apply Syslog Configuration...

Page 62: ...enable or disable the email alert function 2 SMTP Server IP set up the mail server IP address 3 Sender Enter the email address e g switch102 123 com to identify where the event log came from 4 Authentication Mark the check box to enable and configure the email account and password for authentication 5 Mail Account set up the email account e g johnadmin for the switch It must be an existing email a...

Page 63: ...uration When the selected events occur the system will generate a log entry and email notification message System event selection Four selections available Cold Start Warm Start SNMP Authentication Failure and X ring topology change Mark the checkbox to select the event When the selected events occur the system will send the logs Port event selection When a port specific event occurs the system wi...

Page 64: ... com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Event Configuration interface Fault Relay Alarm Power Failure When the check box is marked the Fault LED will light if the power source fails Port Link Down Broken When the check box is marked the Fault LED will light if a port link goes down ...

Page 65: ...Fault Relay Alarm interface SNTP Configuration SNTP allows you to synchronize switch clocks SNTP Client Enables or disables the SNTP function Daylight Saving Time Enables or disables daylight saving time When this function is enabled the time period must be entered UTC Time zone Sets the local time zone Local Time Zone Conversion from UTC Time at 12 00 UTC November Time Zone 1 hour 11am Oscar Time...

Page 66: ...d MDT Mountain Daylight 6 hours 6 am MST Mountain Standard PDT Pacific Daylight 7 hours 5 am PST Pacific Standard ADT Alaskan Daylight 8 hours 4 am ALA Alaskan Standard 9 hours 3 am HAW Hawaiian Standard 10 hours 2 am Nome Alaska 11 hours 1 am CET Central European FWT French Winter MET Middle European MEWT Middle European Winter SWT Swedish Winter 1 hour 1 pm EET Eastern European Russia Zone 1 2 h...

Page 67: ...A Zone 7 8 hours 8 pm JST Japan Standard RUSSIA Zone 8 9 hours 9 pm EAST East Australian Standard GST Guam Standard RUSSIA Zone 9 10 hours 10 pm IDLE International Date Line NZST New Zealand Standard NZT New Zealand 12 hours Midnight SNTP Sever URL Enter the SNTP server IP address Daylight Saving Period Enter the Daylight Saving beginning time and Daylight Saving end time Daylight Saving Offset mi...

Page 68: ...permission to access the switch through a web browser or TELNET for management IP Security Mode When enabled allows management via TELNET and HTTP Enable HTTP Server Mark the box to grant the specified IP addresses web based management permission Enable Telnet Server Mark the box to grant the specified IP addresses TELNET management permission Security IP 1 10 Enter up to 10 IP addresses And then ...

Page 69: ...ly User Authentication interface Port Statistics Port The port number Type Displays the connection speed Link Displays link status Up or Down State Enabled or Disabled Tx Good Packet Displays the number of good packets transmitted Tx Bad Packet Displays the number of bad packets transmitted Rx Good Packet Displays the number of good packets received Rx Bad Packet Displays the number of bad packets...

Page 70: ...s interface Port Control Used to configure and view port settings 1 Port Select the port to configure 2 State Enable or disable the port 3 Negotiation Set the negotiation status of the port 4 Speed Set the port link speed 5 Duplex Set the port to full or half duplex 6 Flow Control Set flow control to Symmetric or Asymmetric in Full Duplex mode The default value is Symmetric 7 Security Set the port...

Page 71: ...en Partner Systems on a link This allows their Link Aggregation Control instances to reach an agreement on the identity of the Link Aggregation Group move the link to that Link Aggregation Group and enable its transmission and reception functions in an orderly manner Link aggregation lets you group up to four consecutive ports into two dedicated connections This feature expands bandwidth to a devi...

Page 72: ...nected to a device that also supports LACP the LACP dynamic trunk group is automatically created 4 Work ports A maximum of four ports can be aggregated at the same time With LACP static trunk group any excess ports are considered standby and can be aggregated if a work port fails If it is local static trunk group the number of ports must be the same as the group member ports 5 Select the ports to ...

Page 73: ...e Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Port Trunk Aggregator Setting interface Aggregator Information Displays static trunk group information Port Trunk Aggregator Information interface State Activity When you had setup the LACP aggregator port state activity can be configured Mark port click Apply The port state activity will change to Active or Passive depending on...

Page 74: ...ts will not perform dynamic LACP trunk because both ports are waiting for an LACP protocol packet from the opposite device Port Trunk State Activity interface Port Mirroring Port mirroring is a method to monitor traffic in switched networks Traffic flowing through the indicated ports can be monitored by a specified port Destination Port Only one port can be selected as the destination mirror port ...

Page 75: ...ercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Port Trunk Port Mirroring interface Rate Limiting Set up each port s bandwidth rate and frame limitation type Ingress Limit Frame type Select the frame type to filter There are four options All Broadcast Multicast Flooded Unicast Broadcast Multicast and Broadcast only Egress Limit The egress rate limit is ALL ...

Page 76: ... to meet the specified rate Ingress Enter the port effective ingress rate The default value is 0 Egress Enter the port effective egress rate The default value is 0 Click Apply VLAN configuration A Virtual LAN VLAN can be thought of as a broadcast domain that exists within a switch or a defined set of switches By grouping switch ports into VLANs traffic flooding is limited since devices can only co...

Page 77: ...tion Port based VLAN With port based VLAN the port is assigned to a VLAN Therefore all devices attached to a given port should be members of the same VLAN As with other VLAN configurations the packets forwarded using this method do not leak into other VLAN domains on the network After the port has been assigned to a VLAN devices on the port cannot send to or receive from devices in other VLANs wit...

Page 78: ...nd Ph 353 91 792444 Fax 353 91 792445 www bb europe com Click Add to add a new VLAN group The maximum number of VLAN groups is 64 Enter the VLAN name group ID the members of the VLAN group Click Apply VLAN Port Based Add interface The VLAN is displayed Use Delete button to delete an unwanted VLAN Use Edit button to modify an existing VLAN group NOTE If the configuration is not saved it will be los...

Page 79: ... specification which allows VLANs to be created across devices from different venders IEEE 802 1Q VLAN uses a technique to insert a tag into the Ethernet frame The tag contains a VLAN Identifier VID When the 802 1Q VLAN is enabled all ports on the switch belong to a default VLAN VID 1 The default VLAN cannot be deleted Up to 64 VLAN groups are supported 802 1q VLAN interface 802 1Q Configuration 1...

Page 80: ...ly Allows ports to be grouped by setting the same VID Trunk Link Extended application of Access Link Allows ports to be grouped by setting the same VID on two or more switches Hybrid Link Both Access Link and Trunk Link 4 Untagged VID assign the untagged frame VID 5 Tagged VID assign the tagged frame VID 6 Click Apply Group Configuration Edit the existing VLAN Group 1 Select the VLAN group in the ...

Page 81: ...o detect a device that is running STP or RSTP protocol RSTP System Configuration RSTP state can be modified After modification click Apply RSTP mode Enable or disable the RSTP Priority 0 61440 a value used to identify the root bridge The bridge with the lowest value has the highest priority and is selected as the root If the value changes the switch must be rebooted The value must be multiple of 4...

Page 82: ...om 1 and 10 Forward Delay Time 4 30 the number of seconds a port waits before changing from its Rapid Spanning Tree Protocol learning and listening state to the forwarding state Enter a value between 4 and 30 NOTE 1 Use the following rule to configure the MAX Age Hello Time and forward Delay Time 2 x Forward Delay Time value 1 Max Age value 2 x Hello Time value 1 2 If the configuration is not save...

Page 83: ...e value must be a multiple of 16 3 P2P Some of the rapid state transactions that are possible within RSTP are dependent upon whether the port concerned can only be connected to exactly one other bridge i e it is served by a point to point LAN segment or can be connected to two or more bridges i e it is served by a shared medium LAN segment This function allows the P2P status of the link to be mani...

Page 84: ... find and solve network problems and plan for network growth Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP System Configuration Community Strings Define and remove community strings 1 String Enter the name of the string 2 RO Read only Enables requests accompanied by this string to display MIB object information 3 RW Read wr...

Page 85: ...ration A trap manager is a management station that receives traps the system alerts generated by the switch If the trap manager is not defined traps will not be issued Create a trap manager by entering the IP address of the station and a community string 1 IP Address Enter the IP address of the trap manager 2 Community Enter the community string 3 Trap Version Select the SNMP trap version type v1 ...

Page 86: ...rope com Trap Managers interface SNMPV3 Configuration Configure the SNMP V3 function Context Table Configure SNMP v3 context table Assign the context name of context table Click Add to add context name Click Remove to remove an unwanted context name User Profile Configure SNMP v3 user table User ID Enter user name Authentication Password Enter the password Privacy Password Enter the private passwo...

Page 87: ...ctronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com SNMP V3 configuration interface ...

Page 88: ...d Click Remove to remove unwanted context name Access Table Configure SNMP v3 access table Context Prefix set up the context name Group Name set up the group Security Level select the access level Context Match Rule select the context match rule Read View Name set up the read view Write View Name set up the write view Notify View Name set up the notify view Click Add to add context name Click Remo...

Page 89: ...when processing 1 frame of the lowest queue 2 frames of the low queue 4 frames of the middle queue and 8 frames of the high queue will be processed at the same time Use the strict priority scheme The highest queue will always processed first Priority Type there are five priority selections available Port base the port priority will follow the assigned Port base High middle low or lowest COS Only t...

Page 90: ...lectronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com QoS Configuration interface ...

Page 91: ...iority level COS priority Set up the COS priority level 0 7 High Middle Low Lowest Click Apply TOS Configuration TOS priority the system provides 0 to 63 TOS priority levels Each level has four types of priority high middle low and lowest The default value is Lowest When an IP packet is received the system will check the TOS level value in the IP packet For example if the TOS level 25 is high and ...

Page 92: ...of message Message Description Query A message sent from the querier IGMP router or switch asking for a response from each host belonging to the multicast group Report A message sent by a host to the querier to indicate that the host wants to be or is a member of a given group indicated in the report message Leave Group A message sent by a host to the querier to indicate that the host has quit bei...

Page 93: ... the redundant path unless a ring member becomes disconnected from the rest of the network When this happens the protocol automatically restores connectivity using the redundant path In the X Ring topology every switch should enable X Ring function and assign two member ports to the ring Only one switch in the X Ring group would be set as the backup switch Other switches are called working switche...

Page 94: ... between the X Ring group and the upper level core switch Enable X Ring Mark the check box to enable the X Ring function Enable Ring Master Mark the check box to set the switch as the Ring Master 1st 2nd Ring Ports Assign two ports as the member ports 1st Ring Port is the working port and 2nd Ring Port is the backup port When 1st Ring Port fails the system will automatically upgrade the 2nd Ring P...

Page 95: ... authentication specification that allows a client to connect to a wireless access point or wired switch but prevents the client from gaining access to the Internet until it proves authority by providing a user name and password which is verified by a separate server System Configuration 1 IEEE 802 1x Protocol Enable or disable 802 1x protocol 2 Radius Server IP Enter the Radius Server IP address ...

Page 96: ...1x System Configuration interface 802 1x Per Port Configuration You can configure 802 1x authentication state for each port The State choices are Disable Accept Reject and Authorize Use the Space key change the state value Reject The port is held in the unauthorized state Accept The port is held in the Authorized state Authorized The port will allow an authentication exchange between the supplican...

Page 97: ... does not try to acquire a supplicant 2 TX Period Sets the period that the port waits before retransmitting the next EAPOL PDU during an authentication session 3 Supplicant Timeout Sets the period the switch waits for a supplicant response to an EAP request 4 Server Timeout Set the period the switch waits for a server response to an authentication request 5 Max Requests Sets the number of authenti...

Page 98: ...dress remains in the switch s address table regardless of whether the device is physically connected to the switch Therefore the switch does not have to re learn a device s MAC address when the disconnected or powered off device reconnects to the network You can add modify delete a static MAC address Add the Static MAC Address You can add static MAC addresses in the MAC table 1 MAC Address Enter t...

Page 99: ...awa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Static MAC Addresses interface MAC Filtering MAC Filtering interface 1 MAC Address Enter the MAC address that you want to filter ...

Page 100: ... com 2 Click Add 3 If you want to delete the MAC address from filtering table select the MAC address and click Delete All MAC Addresses 1 Select the port 2 The selected port of static MAC address information will be displayed 3 Click Clear MAC Table to clear the current port static MAC address information on screen All MAC Address interface Factory Default To reset switch to default configuration ...

Page 101: ...Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Factory Default interface Save Configuration Save configuration changes click Save Flash Save Configuration interface System Reboot Reboot the switch click Reboot System Reboot interface ...

Page 102: ...ting Verify that 24 to 48VDC power is available Do not exceed 48VDC Select the proper cable to construct your network Use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 100Ω Category 3 4 or 5 cable for 10Mbps connections 100Ω Category 5 cable for 100Mbps or 100Ω Category 5e above cable for 1000Mbps connections Ensure that the length of any twisted pair connectio...

Page 103: ...hernet IEEE 802 3u 100Base TX and 100Base FX Fast Ethernet IEEE802 3x Flow Control and Back Pressure IEEE802 3ad Port trunk with LACP IEEE802 1d Spanning Tree IEEE802 1w Rapid Spanning Tree IEEE802 1p Class of Service IEEE802 1Q VLAN Tag IEEE 802 1x User Authentication Radius Protocol CSMA CD Management SNMP v1 v2c v3 management Web interface management Telnet interface management Command Line Int...

Page 104: ...e and forward switching architecture Transfer Rate 14 880 pps for 10Base T Ethernet port 148 800 pps for 100Base TX FX Fast Ethernet port Packet filter 4 types of packet filter rule with different packet combination All of packet Broadcast multicast flooded unicast packet Broadcast multicast packet Broadcast packet only MAC address 8K MAC address table Packet Buffer 1Mbits LED RJ 45 port Link Acti...

Page 105: ...s Power Supply 24 48 VDC Redundant power with polarity reverse protects function and removable terminal block Power consumption 11 28 Watts X Ring 2 ports for X Ring to provide redundant backup feature and the recovery time below 300ms and start by Web interface management The ring port can be defined by Web interface VLAN Port based VLAN IEEE802 1Q Tag VLAN Both of port based and Tag based VLAN g...

Page 106: ...acket only RX packet only Both of TX and RX packet Firmware update TFTP firmware update TFTP backup and restore Relay Alarm Relay output for port breakdown and power source failure Alarm Relay Contact Rating 1A 24VDC Contacts normally open Bandwidth control Ingress packets filter and egress packet limit The egress rate control supports all of packet type and the limit rate range is from 100 kbps t...

Page 107: ...Install DIN rail kit and wall mount ear for wall mount or DIN type cabinet install Operating Temp 40 to 75 Operating Humidity 5 to 95 Non condensing Storage Temperature 40 to 85 Case IP30 Dimensions 2 7 x 4 2 x 6 4 in 7 4 x 10 7 x 16 13 cm EMI FCC Class A CE EN61000 4 2 CE EN61000 4 3 CE EN61000 4 4 CE EN61000 4 5 CE EN61000 4 6 CE EN61000 4 8 CE EN61000 4 11 CE EN61000 4 12 Safety UL cUL CE EN609...