  The Baud Rate is the speed at which communication takes place 

between the PC and the Smart Switch.  It must be specified so that it is 
equal to SW1 – positions 1 – 3  on the Smart Switch. 
 

 

  The Number of Data Bits is the length of each character that gets sent 

from the PC to the Smart Switch.  This value must be specified so that it is 
equal to SW1 – position 4 on the Smart Switch. 
 

 The 

Module must be set so that it is equal to the Smart Switch Module 

which you are using (i.e. PortMUX if you are using a PortMUX). 

   
  The User Defined Character must be set so that it is equal to SW2 on 

the Smart Switch.

Port Address 

COM 1 

03F8h 

COM 2 

02F8h 

COM 3 

03E8h 

COM 4 

02E8h 

 

  

232XS5-1005 

Manual 

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445  

18

 

 

Summary of Contents for 232XS5

Page 1: ...B B Electronics Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 92444 Fax 353 91 92445 www bb europe com 1997 B B Electronics Revised March 2005 2000 B B Electronics No part of this p...

Page 2: ...lation 15 Setup 15 Default Values 16 Selecting Ports 16 Parameters 16 Appendix A ASCII Character Codes A 1 Appendix B Cable Charts B 1 Chart 1 IBM PC DB25 Connector to Master Port B 1 Chart 2 IBM PC D...

Page 3: ...CTS DSR DTR and DCD The 232XS5 has an enhanced timer mode which offers special timer features The timer features can be used to prevent slave devices from receiving preamble commands inadvertently sw...

Page 4: ...4 Table 2 Mode Setup On Jumper Installed Off Jumper Removed X DON T CARE FACTORY DEFAULT Port Configuration In order to determine the proper port configuration of the 232XS5 it is necessary to have a...

Page 5: ...Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 6 Serial Data Configuration In order for the host device that is connected to the master port to select any of the five port...

Page 6: ...nce it is still selected and the letter B will show up on your port A device For information on preventing command codes from being received by slave devices refer to the Enhance Mode section NOTE The...

Page 7: ...0 Fax 815 433 5104 B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 10 NOTE When a port is selected via the Master Port the RTS lines will be ign...

Page 8: ...9 5 min 232XS5 1005 Manual B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland P...

Page 9: ...Expansion Mode Address D C C Address C Slave Port B Slave Port A Slave Port A Address B Slave Port Slave Port A B Slave Port B C Slave Port D E Slave Port E Slave Port Expansion Port E Slave Port D S...

Page 10: ...rs as per their specific needs Comport Baud Rate and Data Bits Character Mode and User Defined Character may also be set for 232XSS and 232XS5 Modules 232XS5 1005 Manual B B Electronics Mfg Co Inc 707...

Page 11: ...ch character that gets sent from the PC to the Smart Switch This value must be specified so that it is equal to SW1 position 4 on the Smart Switch The Module must be set so that it is equal to the Sma...

Page 12: ...ctrl L 44 2C 76 4C L 108 6C l 13 D CR ctrl M 45 2D 77 4D M 109 6D m 14 E SO ctrl N 46 2E 78 4E N 110 6E n 15 F SI ctrl O 47 2F 79 4F O 111 6F o 16 10 DLE ctrl P 48 30 0 80 50 P 112 70 p 17 11 DC1 ctrl...

Page 13: ...2 4 7 5 8 6 6 7 5 8 1 20 4 IBM PC Serial Port DB9 Connector Signal Direction 232XS5 Master Port DCE DB9 Connector 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 B 2 Appendix B 232XS5 1005 Manual B B Electronics PO...

Page 14: ...ignal Direction 232XS5 Ports A E DTE DB9 Connector 1 4 2 3 3 2 4 6 5 5 6 4 7 8 8 7 B 4 Appendix B 232XS5 1005 Manual B B Electronics PO Box 1040 Ottawa IL 61350 PH 815 433 5100 FAX 815 433 5104 Chart...

Page 15: ...onfigured as a DTE port with a modem connected see Chart 3 IBM PC Serial Port DB9 Connector Signal Direction 232XS5 Ports A E DCE DB9 Connector 3 3 2 2 7 6 8 4 6 4 5 5 1 8 4 7 Pins are tied together i...

Reviews: