![background image](http://html.mh-extra.com/html/bandb-armr/vertical-pivot/vertical-pivot_operation-and-maintenance-manual_459657012.webp)
Installation and Operations Manual
— VP Gate Operator
12
B&B ARMR
A Division of B&B Roadway and Security Solutions VP Revision B1
8.
Verify the gate closes completely. The limit switch should stop the gate automatically,
however if the motor is still operating and the gate is fully closed, stop the gate by pressing
the Stop button on the printed circuit board, pressing Stop pushbutton control panel, or by
turning the power switch off.
9.
If necessary make adjustments to the close limit
NOTE: Some air may have become trapped in the hydraulic cylinder and/or lines and may
cause the gate panel to “come down hard”. With use, this air should eventually be removed
by the system. Another cause of the “come down hard” may be the limit switch adjustment.
10.
After making adjustments run the gate a couple of time to verify satisfactory operation.
11.
You are now ready to install any peripheral/secondary safety devices.