9
1 amp fuse (processor protection)
10
Factory connections
7. Secondary Safety Devices
Connecting safety devices to the secondary safety connectors will stop the gate on the detection
of the safety and proceed in the event of clearing the safety. To reverse the gate on the event of a
safety, you must connect the safety device to the loopsafe terminal on connector 3.
*Note: The ROAD and BACK connections are normally open connections
UL Approved Secondary Safety Devices:
Miller Edge
- manufacturer of contact sensors for all types of gates (800-220-EDGE).
website: http://www.milleredge.com
EMX Industries
- manufacturer of non-contact sensors for gates (800-426-9912).
website: http://
www.emxinc.com
IMPORTANT
NOTE:
UL 325 approved secondary
safety devices MUST be
used for the gate installation
to comply with the
requirements of UL 325.
Refer to the UL
approved
manufacturer’s
documentation for proper
installation of secondary
safety devices.