Installation and Operations Manual
— LXL Gate Operator
23
B&B ARMR
A Division of B&B Roadway and Security Solutions 0054-9001UL Revision A2
4.15.2 Maglock Parameter
1.
From the main menu, select ‘Set
Param’.
2.
Press the UP grey arrow key and
scroll through the options to
MAGLOCK?
3.
Press OK.
4.
The S on Switch will start flashing
5.
Use the arrow keys to Off to On
6.
Press OK to save
Now you will need to wire in the
maglock as shown on page 40
4.15.3 Maglock Delay Parameter
When using a Maglock you have an
option to change a delay from when the
close limit is made and the voltage being
applied to the maglock. Default is 1
second. To change this setting;
1.
From the main menu, select ‘Set
Param’.
1.
Press the UP grey arrow key and
scroll through the options to
MAGDELAY
2.
Press OK.
3.
The 0 on the T line will start flashing
4.
Use the UP grey arrow keys toggle
value.
5.
Use the RIGHT or LEFT grey arrow
keys to move with the time frame
6.
Once desired time is entered
7.
Press OK to save
Note: s = seconds, m = minutes, h =
hours
4.16 Maintain Input Parameters
The inputs that cause the gate to open or close has a feature where you can enable or disable a
maintain command. These inputs are Open, Close, Open/Close, and Int Open. Meaning that you
can change the command from a pulsed input to a hold until complete command or set a time
which has to be maintain before input is recognized as a valid input.
MAGLOCK?
Switch-Off
MAGDELAY
T =01:00s
Ta =00:00