Light Weight Taut Wire Mk 15B Operation Manual
14
A pressure manometer, located on hydraulic cabinet is, when pump is
running, indicating max. hydraulic working pressure. The pressure is
manually set and automatically controlled by the hydraulic pressure
regulator valve.
Air pressure manometer for air cylinder pressure (tension) control and
adjustment is located on the air pressure regulator inside the cabinet.
The air dumping valve
is set to dump the tension compensating
cylinder air pressure whenever the taut wire is outside mooring mode.
The set point is adjusted at the bottom of the valve and should give an
air pressure corresponding to 150 kp tension.
4.6
Heating System
Heating elements in electrical motors and outdoor cabinet provides
heating while the main power switch at the local control panel is
switched “OFF” to prevent condensation.