background image

Controller status

System voltage

12v

24V

36V

48V

Dial switch state

Down Down

Down     Up

Up     Down

Up          Up 

Description

The right and left gear both turn to Upward.

Turn the left gear to Downward, Turn the right gear to Upward.

Turn the left gear to Upward, Turn the right gear to Downward

The right and left gear both turn to Upward.

System protection function description

Controller temperature exceed 90

 will close the load and charging efficiency will decrease. 

Temperature less than 85

 will recover.

Battery temperature exceed 55

 will close the load and charging will closed. Temperature less than

 55

 will recover.

1

Overtemperature protection

Decrease the charging efficiency when PV array charging current more than Rate charging current 
and less then 1.25 times of Rate charging current for 60s.
Decrease the charging efficiency when PV array charging current more than 1.25 and less then 1.5 
times of Rate charging current for 5s.
Decrease the charging efficiency when PV array charging current more than 1.5 times of Rate 
charging current for 1s.

2

Charging protection

The controller will start the over discharge protection and close the load when the battery voltage is
 less than over discharge voltage and duration 5s.
The controller will start the over discharge recovery protection when the battery voltage exceed the 
over discharge recovery voltage.The next night will remove automatically.

3

Over discharge protection

Short circuit: 
The first time short circuit in one day will recover after 5s later.
The second time will recover after 10s later.
The third time will recover after 15s later.
The forth time will recover after 20s later.
The fifth time or more than five times will recover after 4hours later.

4

Short circuit protection

Also can recover by long press the key!

Over-load protection: 
Close the load when load current more than Rate load current also less than 1.25 times of Rate load 
current for 60 seconds;
Close the load when load current more than 1.25 also less than 1.5 times of Rate load current for30 
seconds;
Close the load when load current more than 1.5 also less than 3 times of Rate load current for 5 seconds;

5

Over load protection

Recovery normal after overload stop 60s later, not have the limited times.

This controller including the PV array, battery and load reverse connection protection.

6

Reverse connection protection

Operating mode

LED Display

00

01

02

03

04

05

06

07

Mode

 

Purely light-operated

LED Display

08

09

10

11

12

13

14

15

Recover after decrease charging efficiency for 1min. 

Light-op time-controlled 

for 1 hour

Light-op time-controlled 

for 2 hours

Light-op time-controlled 

for 3 hours

Light-op time-controlled 

for 4 hours

Light-op time-controlled 

for 5 hours

Light-op time-controlled 

for 6 hours

Light-op time-controlled 

for 7 hours

Mode

 

Light-op time-controlled 

for 8 hours

Light-op time-controlled 

for 9 hours

Light-op time-controlled 

for 10 hours

Light-op time-controlled 

for 11 hours

Light-op time-controlled 

for 12 hours

Light-op time-controlled 

for 13 hour

Light-op time-controlled 

for 14 hours

Always on mode

Night

Daytime

In charging

System over voltage

System voltage alternative

If the model which voltage set by manual, before setting, please kindly check the system voltage. 

This controller support 12/24/36/48V system. Please choose the voltage before use

ON

1

2

Truth Table

System

12V
24V
36V
48V

Position

LED Light     Indications         Status            Functions

Charging
Indication

Load
Indication

Always off

Always on

Twinkle slow

Twinkle fast

Always off

Always on

Twinkle slow

Twinkle fast

Load off

Load on

Overload

Short circuit

The model which voltage will recognized automatically,this dial switch not effect and the controller 

will recognize the battery voltage by itself.