Controller status
System voltage
12v
24V
36V
48V
Dial switch state
Down Down
Down Up
Up Down
Up Up
Description
The right and left gear both turn to Upward.
Turn the left gear to Downward, Turn the right gear to Upward.
Turn the left gear to Upward, Turn the right gear to Downward
The right and left gear both turn to Upward.
System protection function description
Controller temperature exceed 90
℃
will close the load and charging efficiency will decrease.
Temperature less than 85
℃
will recover.
Battery temperature exceed 55
℃
will close the load and charging will closed. Temperature less than
55
℃
will recover.
1
、
Overtemperature protection
Decrease the charging efficiency when PV array charging current more than Rate charging current
and less then 1.25 times of Rate charging current for 60s.
Decrease the charging efficiency when PV array charging current more than 1.25 and less then 1.5
times of Rate charging current for 5s.
Decrease the charging efficiency when PV array charging current more than 1.5 times of Rate
charging current for 1s.
2
、
Charging protection
The controller will start the over discharge protection and close the load when the battery voltage is
less than over discharge voltage and duration 5s.
The controller will start the over discharge recovery protection when the battery voltage exceed the
over discharge recovery voltage.The next night will remove automatically.
3
、
Over discharge protection
Short circuit:
The first time short circuit in one day will recover after 5s later.
The second time will recover after 10s later.
The third time will recover after 15s later.
The forth time will recover after 20s later.
The fifth time or more than five times will recover after 4hours later.
4
、
Short circuit protection
Also can recover by long press the key!
Over-load protection:
Close the load when load current more than Rate load current also less than 1.25 times of Rate load
current for 60 seconds;
Close the load when load current more than 1.25 also less than 1.5 times of Rate load current for30
seconds;
Close the load when load current more than 1.5 also less than 3 times of Rate load current for 5 seconds;
5
、
Over load protection
Recovery normal after overload stop 60s later, not have the limited times.
This controller including the PV array, battery and load reverse connection protection.
6
、
Reverse connection protection
Operating mode
LED Display
00
01
02
03
04
05
06
07
Mode
Purely light-operated
LED Display
08
09
10
11
12
13
14
15
Recover after decrease charging efficiency for 1min.
Light-op time-controlled
for 1 hour
Light-op time-controlled
for 2 hours
Light-op time-controlled
for 3 hours
Light-op time-controlled
for 4 hours
Light-op time-controlled
for 5 hours
Light-op time-controlled
for 6 hours
Light-op time-controlled
for 7 hours
Mode
Light-op time-controlled
for 8 hours
Light-op time-controlled
for 9 hours
Light-op time-controlled
for 10 hours
Light-op time-controlled
for 11 hours
Light-op time-controlled
for 12 hours
Light-op time-controlled
for 13 hour
Light-op time-controlled
for 14 hours
Always on mode
Night
Daytime
In charging
System over voltage
System voltage alternative
If the model which voltage set by manual, before setting, please kindly check the system voltage.
This controller support 12/24/36/48V system. Please choose the voltage before use
ON
1
2
Truth Table
System
12V
24V
36V
48V
Position
LED Light Indications Status Functions
Charging
Indication
Load
Indication
Always off
Always on
Twinkle slow
Twinkle fast
Always off
Always on
Twinkle slow
Twinkle fast
Load off
Load on
Overload
Short circuit
The model which voltage will recognized automatically,this dial switch not effect and the controller