background image

GRSM17 

Pneumatic 

Center Punch 

Tool

Tool Overview:

The GRSM17 has been designed to automatically tension, lock and cut-off scrap tails of CP 
style clamps.  Type 201 Stainless Steel and Galvanized Carbon Steel, 5/8” wide CP style 
clamps can be easily installed on hose assemblies or objects chosen by the operator. 

The GRSM17 will sense when the desired clamp tail tension is achieved and automatically 
switch to finalize the clamp.  The completion of each clamp includes setting the lock while 
simultaneously cutting off the excess clamp tail without requiring an assembly roll-up action.

Operating tip

: Choose a clamp diameter close to the size of the diameter of the object 

being clamped. An oversized clamp may cause the End-of-Stroke safety switch to activate 
and prevent finalizing the clamp with a lock and cut-off (see page 6, #6 and page 7, #4).

The GRSM17 directs compressed air through a foot pedal control to cycle the tool and 
complete the installation of BAND-IT Center Punch Clamps. The foot pedal has a dual 
action,  forward (toe) and reverse (heel).  During normal operation, the operator should fully 
depress the foot pedal forward (toe), not removing this pedal pressure until the cycle has 
completed and clamp tail is ready to be removed from the tool. 

Upon completion of the tension, lock and cut-off cycle, the operator should depress the heel 

Tool Overview 
and Installation

Document# P47050 Rev. -

© Copyright 

BAND-IT-IDEX, Inc. 2008

All rights reserved

www.BAND-IT-IDEX.com

BAND-IT-IDEX, Inc.

A Unit of IDEX Corporation

4799 Dahlia Street Denver, CO 80216-3070 USA

P: 1-800-525-0758   F: 1-800-624-3925

3

Upon completion of the tension, lock and cut-off cycle, the operator should depress the heel 
end of the pedal and remove the scrap clamp tail from the CP head.

Operating tip

: Operation can be stopped at any time by removing the operator’s foot 

completely from the foot pedal control. 

Tool Installation:

1.

Recommended work bench height is 34” – 40”.  This height is suggested as the optimum 
range for operator comfort and safety during typical clamp applications.  Locate the tool on a 
solid surface making sure of ample clearance on either side for handling hose assemblies of 
various lengths.

2.

The air tool must be firmly secured as close to the front edge of the work bench as possible. 
This will reduce interference of hose assemblies during clamp application.  Install tool using 
5/16” diameter fastening hardware (not supplied with tool).

3.

Use of the GRSM17 without properly maintained filtration and lubrication will void the 
warranty. See page 4 for additional information on air supply requirements.

Summary of Contents for GRSM17

Page 1: ...Denver CO 80216 3070 USA P 1 800 525 0758 F 1 800 624 3925 1 Table of Contents Page Information 2 Safety Guidelines and Warranty 3 Tool Overview and Installation 4 Air System Requirements 5 Setting Co...

Page 2: ...er CO 80216 3070 USA P 1 800 525 0758 F 1 800 624 3925 2 harm Disconnect air supply prior to maintenance and disassembly of tool components Important advice and warning to user Read before applying cl...

Page 3: ...eted and clamp tail is ready to be removed from the tool Upon completion of the tension lock and cut off cycle the operator should depress the heel Tool Overview and Installation Document P47050 Rev C...

Page 4: ...blockage of air mufflers and a dirty environment Solvents Liquids such as solvents or cleaners should never be added to the air system through air lines Air System Requirements Oil drip rate Document...

Page 5: ...X com BAND IT IDEX Inc A Unit of IDEX Corporation 4799 Dahlia Street Denver CO 80216 3070 USA P 1 800 525 0758 F 1 800 624 3925 5 pressure setting from below by increasing pressure Suggested settings...

Page 6: ...rting an object that is soft and safe to hold into the end of the fitting for additional support may help Large diameter hose assemblies should be held securely with both hands Keep hands away from cl...

Page 7: ...t lock Trouble Shooting Guide Document P47050 Rev Copyright BAND IT IDEX Inc 2008 All rights reserved www BAND IT IDEX com BAND IT IDEX Inc A Unit of IDEX Corporation 4799 Dahlia Street Denver CO 8021...

Page 8: ...ce Frequency Component Check Preventative Maintenance Schedule Document P47050 Rev Copyright BAND IT IDEX Inc 2008 All rights reserved www BAND IT IDEX com BAND IT IDEX Inc A Unit of IDEX Corporation...

Page 9: ...to BAND IT Center Punch Head Information Document P47050 Rev Copyright BAND IT IDEX Inc 2008 All rights reserved www BAND IT IDEX com BAND IT IDEX Inc A Unit of IDEX Corporation 4799 Dahlia Street De...

Page 10: ...ent P47050 Rev Copyright BAND IT IDEX Inc 2008 All rights reserved www BAND IT IDEX com BAND IT IDEX Inc A Unit of IDEX Corporation 4799 Dahlia Street Denver CO 80216 3070 USA P 1 800 525 0758 F 1 800...

Page 11: ...r Pressure Gauges 2 Air Pressure Regulators 2 Air Connections for Supply to Cut off Cylinder End of Stroke Indicator Document P47050 Rev Copyright BAND IT IDEX Inc 2008 All rights reserved www BAND IT...

Page 12: ...t BAND IT IDEX Inc 2008 All rights reserved www BAND IT IDEX com BAND IT IDEX Inc A Unit of IDEX Corporation 4799 Dahlia Street Denver CO 80216 3070 USA P 1 800 525 0758 F 1 800 624 3925 12 LENGTH INC...

Page 13: ...rranty html Factory Services Additional Factory Support and Tool Service Document P47050 Rev Copyright BAND IT IDEX Inc 2008 All rights reserved www BAND IT IDEX com BAND IT IDEX Inc A Unit of IDEX Co...

Reviews: