3. Once it receives a signal from the baby unit, the visual level meter 17 will light up. 

The number of segments being lighted up vary along with the sound. This feature is 

useful  in  case  the  parents  prefer  to  turn  down  the  speaker  volume  to  keep  the 

environment quiet.

4. The speaker volume can be adjusted using the        button 14 and         button 15 . 

Each  press  of  button  will  change  the  volume  by  1  step  which  is  correspondingly 

indicated  by  the  visual  level  meter  17  .  There  are  total  5  volume  levels,  more 

segments shown in visual level meter 17 means higher volume. When the volume 

setting is at minimum, further press of      button 14 will cause the speaker 21 to be 

totally muted with the        icon 20 being lighted up.

5. This unit is equipped with a vibration alert. Press the        button 16 and the        icon 

19 will show up. Once the received baby’s voice is loud enough, the vibrator starts 

to function. This feature is useful when the parent is working under noisy environ

-

ment (e.g. vacuum cleaning). To save battery power, it is recommended not to use 

the vibration alert frequently. To switch off vibration, press the       button 16 again 

and the       icon 19 goes off.

6. Once this unit is beyond the communication range of baby unit for over 30 sec, an 

out of range alarm will be heard together with segments of the visual level meter 17 

flashing to alert the parents. The alarm sound is independent of whether the speaker 

is muted or not. This alarm will go off only when the parent unit falls back within the 

communication range of baby unit.

N.B.  This  alarm  will  also  be  heard  in  case  the  baby  unit  is  switched  off,  or  its 

battery has run down, or its power is cut off, or the pairing is not properly done 

between the baby and parent unit.

7. The condition of the Li battery pack is shown by the power on/low battery icon    18 . 

When battery level becomes running low, the        icon 18 turns red and an alarm will 

be  heard,  reminding  the  parents  to  charge  up  the  battery  using  the  supplied AC 

adapter.

8. Each time the buttons are pressed, a beep tone will be heard. To eliminate this  beep 

tone, press and hold the       button 14 for 2 sec until a second beep tone is heard. 

To resume the beep tone, press and hold the       button 15 for 2 sec until a beep tone 

is heard. Whenever the unit is switched off and then on again, the beep tone will 

resume automatically.

9

Summary of Contents for BC-62

Page 1: ...Instruction Manual ...

Page 2: ...it Features Full digital technique operating in the 902 000MHz 928 000MHz with zero interference Automatic search and hop to free channel Operating range of 800m in open space Low radiating power only 8 of normal DECT and 40 of ECO DECT Automatic power reduction system further reduce radiation level to half when baby unit and parent unit are close to each other Night light with adjustable intersit...

Page 3: ... BC 62 DIGITAL TECHNOLOGY AND APRS This baby monitor employs full digital technology with zero interference The unit can automatically select free channel or hop to free channel during communication to avoid interference from other electronic devices In addition thanks to the Automatic Power Reduction System APRS which senses the distance between baby and parent unit and automatically reduces the ...

Page 4: ...olarities indication N B For best performance do not mix use old and new batteries or alkaline and rechargeable batteries 2 Operation using AC adapter The baby unit can be operated on AC mains using the supplied 5V AC adapter Connect the output plug of AC adapter to USB port 12 of the baby unit make sure the polarity is correct The battery will be cut off once the AC adapter s output plug is inser...

Page 5: ... to a certain level the AC adapter will automatically start charging up the battery again 5 B Parent unit 1 Operation from battery pack The Li polymer battery pack is already installed in the unit To exchange battery pack press and open the battery cover remove the belt clip in the direction as shown take out the battery pack and disconnect from socket Note Before using the parent unit for the fir...

Page 6: ...ght intensity adjustment button Night Light VOX control button Night Light Power On Battery low icon Transmit icon Night Light VOX icon Micophone always ON icon Microphone USB port Power On Off button Volume down button Volume up button Vibration button Visual level meter Out of range icon Power On Battery Low Charging icon Vibration icon Speaker mute icon Speaker USB port 12 13 14 15 16 17 18 19 ...

Page 7: ...wait until the power on icon 18 starts flashing green Release both buttons 13 15 3 Now press and hold the button 11 of baby unit 4 Press the power ON OFF button 1 and wait until the power on icon 7 starts flashing green Release both buttons 1 11 5 Now short press the power ON OFF button 1 of baby unit 6 If pairing is successful the power on icons 18 7 on both baby parent unit should stop flashing ...

Page 8: ...by mode a few seconds after the microphone 11 stops picking up any sound and the transmit icon 8 will go off Except when the unit is set in continuous transmission mode the transmit icon 8 will stay steady on 5 The night light 6 can be set permanently ON by pressing the button 4 Each press of button 4 will increase the level of light intensity maximum 5 levels The night light 6 can also be set to ...

Page 9: ...uently To switch off vibration press the button 16 again and the icon 19 goes off 6 Once this unit is beyond the communication range of baby unit for over 30 sec an out of range alarm will be heard together with segments of the visual level meter 17 flashing to alert the parents The alarm sound is independent of whether the speaker is muted or not This alarm will go off only when the parent unit f...

Page 10: ...formed within a temperature range of 19 C to 50 C Do not open the cabinet no serviceable parts inside The BC 62 should not be exposed to dripping splashing and that no objects filled with liquids such as vases shall be placed on it Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent Batteries battery pack or batteries installed shall not be exposed to ex...

Page 11: ...t is switched on Baby unit is located near other electrical appliances Many steel structures between baby parent unit Baby unit battery has run down SOLUTION Adjust mic sensitivity higher using button 3 Replace with new battery or check connection Adjust mic sensitivity lower using button 2 Set the unit to become voice activated Replace with new battery or use AC adapter Move the baby parent unit ...

Page 12: ...12 All European Countries except Austria Georgia Greece Norway Russian Federation Spain Sweden The Netheriands Ukaine ...

Page 13: ...13 ...

Page 14: ...nt off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help IC This device...

Reviews: