ENGLISH
6 / 36
0006160008_201711
TECHNICAL SPECIFICATIONS
MODEL
TBG 85 MC
TBG 120 MC
TBG 150 MC
MAXIMUM NATURAL GAS HEAT POWER
kW
850
1200
1500
MINIMUM NATURAL GAS HEAT POWER
kW
170
240
300
¹) NATURAL GAS EMISSIONS
mg/kWh
Class 2
Class 2
Class 2
OPERATION
Two-stage progressive /
modulating
Two-stage progressive /
modulating
Two-stage progressive /
modulating
NATURAL GAS TRANSFORMER 50 Hz
26 kV 40 mA - 230 V
26 kV 40 mA - 230 V
26 kV 40 mA - 230 V
MAXIMUM NATURAL GAS HEAT RATE
Stm³/h
90
127
158.7
MINIMUM NATURAL GAS HEAT RATE
Stm³/h
18
25.4
31.8
MAXIMUM NATURAL GAS PRESSURE
hPa (mbar)
360
360
360
NATURAL GAS MINIMUM PRESSURE
hPa (mbar)
31
20
21.7
PROPANE GAS MAXIMUM THERMAL POWER
kW
850
1200
1500
PROPANE GAS MINIMUM THERMAL POWER
kW
170
240
300
PROPANE GAS MAXIMUM HEAT CAPACITY
Stm³/h
34.7
49
61.3
PROPANE GAS MINIMUM HEAT CAPACITY
Stm³/h
6.9
9.8
12.3
PROPANE GAS MAXIMUM PRESSURE
hPa (mbar)
360
360
360
PROPANE GAS MINIMUM PRESSURE
hPa (mbar)
31
30
46
²)PROPANE EMISSIONS
mg/kWh
Class 2
Class 2
Class 2
50 Hz FAN MOTOR
kW
1.1
1.5
2.2
60Hz FAN MOTOR
kW
1.1
1.5
2.6
ABSORBED ELECTRICAL POWER* 50Hz
kW
1.6
2
2.8
ABSORBED ELECTRICAL POWER* 60Hz
kW
1.6
2
3.2
50 Hz POWER SUPPLY VOLTAGE
3N~ 400V ± 10%
3N~ 400V ± 10%
3N~ 400V ± 10%
DEGREE OF PROTECTION
IP54
IP54
IP54
FLAME DETECTOR
IONISATION PROBE
IONISATION PROBE
IONISATION PROBE
EQUIPMENT
LME 22..
LME 22..
LME 22..
AIRFLOW REGULATION
MECHANICAL CAM
MECHANICAL CAM
MECHANICAL CAM
SOUND POWER***
dBA
WEIGHT WITH PACKING
kg
78
87
91
Calorific power lower than reference conditions 15° C, 1013 hPa (mbar):
Natural gas: Hi = 9.45 kWh/Stm³ = 34.02 MJ/Stm³
Propane gas: Hi = 24.44 kWh/Stm³ = 88.00 MJ/Stm³
For different types of gas and pressure values, please contact our sales department.
* Total absorption at start with ignition transformer on.
** The acoustic pressure measured with burner operating at maximum rated thermal output refers to the manufacturer's laboratory
environment conditions and cannot be compared to measurements carried out in different locations.
*** Acoustic power was obtained characterizing the manufacturer's laboratory with a sample source; this measurement has a class 2
accuracy (engineering class) with a standard deviation of 1.5 dB(A).
CO emissions, natural gas/propane ≤ 100 mg/kWh
¹) NATURAL GAS EMISSIONS
Classes defined according to Standard EN 676.
Class
NOx emissions in mg/kWh - natural gas
1
≤ 170
2
≤ 120
3
≤ 80
²) PROPANE EMISSIONS
Classes defined according to Standard EN 676.
Class
NOx emissions in mg/kWh - propane gas
1
≤ 230
2
≤ 180
3
≤ 140
Summary of Contents for TBG 85 MC
Page 2: ......
Page 36: ...ITALIANO 34 36 0006160008_201711 SCHEMI ELETTRICI...
Page 38: ......
Page 72: ...ENGLISH 34 36 0006160008_201711 WIRING DIAGRAMS...
Page 74: ......
Page 75: ......