4 / 15
0006081083_200705
E
N
G
L
I
S
H
TECHNICAL DATA
TBG
55ME
TBG
85ME
TBG
120ME
TBG
150ME
TBG
210ME
THERMIC CAPACITY
MAX kW
550
850
1200
1500
2100
MIN kW
110
170
240
300
400
OPERATION
Two-stage progressive/ modulating versions
NOx EMMISION
mg/kWh
< 120 (Classe II EN 676)
MOTOR
kW
0,55
1,1
1,5
2,2
3
r.p.m.
2800
2800
2800
2800
2800
ABSORBED ELECTRICAL POWER*
kW
0,66
1,20
1,60
2,40
3,2
line fuse
A
400 V
6
6
10
10
16
IGNITION TRANSFORMER
26 kV - 40 mA – 230 V / 50 Hz
VOLTAGE
3N ~ 400 V ±10%- 50 Hz
PROTECTION RATING
IP 40
FLAME DETECTOR
IONISATION PROBE
NOISE**
dBA
72
73
75,5
79
85
WEIGHT
kg
76
78
87
91
94
Natural Gas (G 20)
FLOW RATE
MAX
m³n/h
55,3
85,5
120,7
150,9
211,2
MIN
m³n/h
11
17
24,1
30,2
40,3
PRESSURE
MAX
mbar
500
*) Total absorption at start with ignition transformer on.
**) Noise levels measured by the manufacturer in the laboratory with burner running on test boiler, at maximum nominal thermal output.
TECHNICAL DATA
TBG
TBG
TBG
TBG
TBG
55ME
85ME
120ME
150ME 210ME
BURNER FIXING FLANGE
2
2
2
2
2
ISOLATING GASKET /
1
1
1
1
1
STUD BOLTS
N° 4
N° 4
N° 4
N° 4
N° 4
M 12
M 12
M 12
M 12
M 12
EXAGONAL NUTS
N° 4
N° 4
N°4
N° 4
N° 4
M 12
M 12
M 12
M 12
M 12
FLAT WASHERS/
N° 4
N° 4
N° 4
N° 4
N° 4
Ø 12
Ø 12
Ø 12
Ø 12
Ø 12
STANDARD ACCESSORIES
Summary of Contents for TBG 55ME
Page 2: ......
Page 4: ......
Page 6: ......
Page 22: ......
Page 38: ......
Page 54: ......
Page 70: ......
Page 86: ......
Page 102: ...99 102 0006081083 _200705 ...
Page 103: ...100 102 0006081083 _200705 ...