20
FEED PLANT
PUMP AS 67
N°0002900510
Rev. 05/05/97
H
= Measurement between minimum
oil level and pump axis
L
= Max. legth of suction line, including
vertical lifts
For each bend of valve deduct
0,25 m.
N.B. For any missing devices in the
pipping, conform to existing regulations.
Max. pressure on suction and return = 1,5 bar
Max. pressure on suction and return = 1,5 bar
Quote P = 3,5 m (max)
1
Oil tank
6
Suction line
2
Feed line
7
Return line
3
Filter
8
Fire valve
4
Burner
9
Non return valve
5
Degasifier
GRAVITY FEED FROM THE BOTTOM OF OIL TANK
1
Oil tank
6
Suction line
3
Filter
7
Return line
4
Burner
10
Foot valve
SUCTION FEED
1
Oil tank
7
Return line
3
Filter
8
Fire valve
4
Burner
9
Non return valve
6
Suction line
10
Foot valve
GRAVITY FEED OVER THE TOP OF OIL TANK
H
METERS
Total lenght
l. meters
Ø i. 12 mm
1
30
2
35
3
40
4
45
H
METERS
Total lenght
l. meters
Ø i. 12 mm
1
30
2
35
3
40
4
45
H
METERS
Total lenght
l. meters
Ø i. 12 mm
Ø i. 14 mm
0,5
27
51
1
23
43
1,5
19
35
2
15
27
2,5
10
20
3
7
13
3,5
--
6