ELECTRICAL CONNECTIONS
The monophase power supply line must have a switch with fuses.
For the electrical connections (line and thermostats), follow the
attached wiring diagram. To carry out the connection of the burner
to the power supply line proceed as follows:
1) Insert the 7 and 4 pole plugs for version "P", in the appropriate
sockets located below the electrical panel base as shown in
figure 1.
2) To reach the electrical components, loosen the two screws (1),
gently pull back the cover to detach it from the electrical panel
base (fig. 2) then lift it up.
3) Re-close the lid taking care to position the two hooks (4) cor
-
rectly in their respective housing (fig. 3).
!
only qualified technicians may open the burner’s electrical
panel.
The electric motor is equipped with thermal protector with
automatic reset that stops the unit in case of overheating.
CAUTION / WARNING
In case of lock out it is necessary to check that the motor is
not faulty and search for the possible causes of its heating.