FMS ACK; J1939 FMS request; J1939 FMS
(500kbps); List of light vehicles with CAN bus
support (periodically updated);
5.7.2 F_Can2FunctionSelect
Selects CAN function. Usually used to read
Tachopgraph with FM Tacho.
5.8 F_EIA485FunctionSelect
RS485* function select. Enables RS485 input reading.
Used for LLS*sensors and J1708*. ES4 sensor reading
– EPSILON fuel level sensors. RS485 Keypad. Tyre
pressure sensors.
5.9 F_RS232FunctionSelect
LLS sensor reading – OMNICOMM fuel level sensors
connected via RS232; NMEA output – GPS
information transfer from our device to external
device; ES2 sensor reading – EPSILON fuel level
sensors; Terminal – device works like communication
terminal between monitoring platform and external
device (sends information in text format); CAN LOG –
work with additional CAN bus module “CAN-LOG”;
RFID TYP A – specific RFID card reader; ADP-400 C
– Rx input is used for communication between FM
Blue and ADP CAN alarm system (just for 5.4 and 5.5
FM Blue+ devices). “6 pin Light 1 Wire power
supply” function is to be used if connecting 1 Wire
sensors to the FM Light devices. Datacold temperature
reading. And more.
5.a F_NewConectionsToInternetLimiter
Limits next possible connection to internet (value
expressed in seconds)
5.b F_Timer1
Special structure for internal timer signal
5.c F_Timer1_GMT
Used to set GMT value.
5.d F_Timer2_Control
Special structure for internal timer signal
5.e F_Timer2_Threshold
Time threshold expressed in seconds. Used with 5.d
function
5.f F_OUT1_Control
Function for OUT1 output control. Works in six
modes: off1 – output disabled, but can be controlled
with GPRS commands; on (minus) – enabled; off2 –
disabled; long – long pulses – two long impulses; short
– short – short pulses – three short impulses; short –
long – short pulses – one short, one long and one short
impulse;
5.g F_OUT2_Control
Function for OUT2 output control. Works in three
modes: off1 – output disabled, but can be controlled
with GPRS commands; on (minus) – enabled; off2 –
disabled;
5.h F_OUT3_Control
Function for OUT3 output control. Works in three
modes: off1 – output disabled, but can be controlled
with GPRS commands; on (minus) – enabled; off2 –