User’s Manual
6
(hereinafter referred to as “boiler”) s produced in accordance with TU 4931-011-26985921-2012 (GOST R
51733-2001, GOST 20548-93) standards. The boiler is designed for heating dwelling and non-dangerous
industrial premises with an area up to 240 m, and also for domestic hot water supply (hereinafter referred to as
- DHW) for sanitary use.
2.2.
Technical characteristics
________________________________________________________________________________ Table 1
NAME OF THE CHARACTERISTIC
UOM
BaltGaz NEVALUX- 8224
Type of gas
Natural G20 / Liquefied G30
Family; group of gas
2-е; Н / 3-е; B/P
Gas pressure in the duct
kPa
1,3 - 2,0/2,9
Rated heating effect
kW
24,0
Rated heating power
kW
26,7
Rated gas consumption
m3/h
2,95/1,00
Minimal heating effect
kW
8,9
Performance index at rated heating power , at least
%
90,0
Performance index at rated heating power 30%, at least than
%
88,0
CH
Temperature regulation range
°С
30-85
Heat carrier operating pressure
MPa
01-02
Maximum heat carrier pressure
MPa
0,3
Volume of inserted expansion tank
L
6,0
Air pressure in the expansion tank
MPa
0,1
D
H
W c
ir
cui
t
Water consumption at heating for T=25 °С
l/min
14,0
Temperature regulation range
°С
Operating water pressure
MPa
0,02 ■ 0,60
Minimal water pressure, Рmin
MPa
0,015
Maximum water pressure, Рmax
(at water heat expansion pressure must not exceed this
value)
MPa
1,0
Minimal water flow for switching the boiler on
l/min
2,5
Minimal water flow for switching the boiler off
l/min
1,5
Specific water consumption, D
dm
3
/mi
n
11,6
Mass consumption of combustion products
g/s
17,0 / 18,5
Average combustion products temperature
°С
140
Type of combustion products outlet
Forced
Heat carrier
Water, Propylenglycolum
Heat carrier circulation type
Airtight forced circulation
Ignition type
Automatic ignition, electronic ignition
Maintenance of set temperature
Automatically kept with accuracy ±1 °С
Temperature indication
LCD display
Rated power tension
V
220 ±10%
Rated electric current frequency
Hz
50
Maximum electric power consumption
kW
0,125
Safety fuse
А
2
Electro security class
I
Protection rate
IP X4D
Overall dimensions: height widths x depth
mm
720x410x326
Net/ Gross weight
kg
34,0 / 36,5
C
onnec
ti
on
di
m
ens
ions
Gas inlet
inch
G3/4
CH inlet and output
inch
G3/4
DHW circuit inlet and output
inch
G1/2
Inlet air orifice / Output orifice for combustion
products (for coaxial pipes)
mm
Ø 100 / Ø60
(Inlet air orifice / Output orifice for combustion
products (for separate pipes)
mm
Ø 80 / Ø80