3. INSTALLATION
IMPORTANT: Installation (plumbing, construction and/or electrical) must be performed by authorized
professionals and according to all local laws and regulations Improper and unauthorized installation
could be dangerous to the users and the products should not be used in such case. The manufac-
turer assumes no liabilities of any kind in case of damage that results from improper installation, use
of the product and violation of transport and warehousing conditions.
3.1. TRANSPORTATION AND WAREHOUSING
• Product warehousing and transport must be carried out according to the marking on the packing.
Storage conditions: 0°C…+40°C; relative humidity (RH) max 95%.
• When receiving a packed product transported in winter conditions (transportation temperature be-
low 0°C/32°F) the product must be stored at room temperature (cond15…+30°C/+59…+86°F,
max RH 95 %) for 24 hours to be warmed up before installation and operation. Installing the unit and
starting it up without prior slow warming period may result in serious damage.
3.2. INSTALLATION REQUIREMENTS
• The room should be with ambient temper15ºC...+40ºC (+59°F…+86°F) and RH max 85%.
• Installation site must meet the requirements set forth according to all applicable local laws and regu-
lations concerning the bathroom installation products including plumbing and electrical installation
requirements.
• The unit must be installed on an even dry solid floor surface and leveled.
• Floor must have central floor drainage for drainage connection and emergency draining in order to
avoid flooding (in case of plumbing failure).
3.3. INSTALLATION
• Product should be leveled using the adjustable legs. Adjust the legs to achieve the required height
and level the product horizontally. Fasten the legs with counter nuts.
• Fill in the spaces between the product and the wall with silicone sealant if necessary.
3.4. WATER CONNECTION REQUIREMENTS
• Products drainage tube should be connected with the drainage system with flexible hose.
• Product has drainage tube with diameter of 50 mm.
• The product’s drainage system is designed for connecting to self flowing household drainage sys
-
tem. The drainage rate corresponds to standard drainage rate of bathtubs and shower cabins drain-
age rate - 0,9 l/sec. Drainage tubes must be designed and installed with tilt that guarantees self clean-
ing of the drainage tubes – i = 0,02…0,03.
• For normal operation incoming cold water must be with tempe10...+15°C (+50...+59°F) and
hot water with tempe50…+60°C (+122…+140°F). Water with temperature exceeding 60°C
can harm bath tubs material.
• Both cold and hot water supply must have shutoff valves (open/close) that enable regular easy open-
ing and closing of water supply.
• The supply water for this unit must be mechanically filtered. In order to avoid the damage to the unit
subparts, non-soluble solid elements in the supply water must be less than 50 mcr. In order to guar-
antee that, it is necessary to install mechanical water filters (50 mcr filtering and 2000 l/h flow rate).
Servicing of filters has to be done according to filter manufacturer’s instructions.
• Optimal water pressure is 3 bars. Minimal allowable pressure is 1,5 bar and maximal 4 bars. If the
water pressure in the building is not in the limits stated here, then pressure reducers must be installed
before cold and hot water inlets. High water pressure may damage or cause problems in the work of
mixer and other equipment.
• Pressure difference in between cold and hot water supply must not exceed 1 bar.
• While installing a bath mixer, connect the mixer with earthing bars of the bath’s frame, using wire of
2,5 mm² of cross section.
Summary of Contents for TETRIS
Page 1: ...TETRIS Paigaldusjuhend Installation manual...
Page 2: ...2...
Page 10: ...10 2013_TETRIS_INSTAL 3 1 5 4 1 2 5 1 5 5 2 II 230 400 10 5 TN S TT IT 30 2 5 5 6...
Page 11: ...11 2013_TETRIS_INSTAL 6 Xonyx Xo nyx Xonyx 6 1 6 2 Xonyx Xonyx 6 3...
Page 12: ...12 2013_TETRIS_INSTAL 6 4 6 5 6 6...
Page 13: ...13 2013_TETRIS_INSTAL...
Page 15: ...15 2013_TETRIS_INSTAL...
Page 16: ...16 2013_TETRIS_INSTAL R R Q Q A R Q Q A C R C...
Page 17: ...17 2013_TETRIS_INSTAL INSIDE EasyClean INSIDE EasyClean INSIDE EasyClean...
Page 18: ...18 2013_TETRIS_INSTAL R C...
Page 19: ...19 2013_TETRIS_INSTAL R C R C R C...
Page 20: ...20 2013_TETRIS_INSTAL...
Page 21: ...21 2013_TETRIS_INSTAL R D...
Page 22: ...22 2013_TETRIS_INSTAL R D...
Page 23: ...23 2013_TETRIS_INSTAL...
Page 24: ...24 2013_TETRIS_INSTAL 49 50 51 52 53 54 J K G H...
Page 25: ...25 2013_TETRIS_INSTAL 55 56 57...