MOL81 485 1312/MOL81 485 1337
MOL81 485 1312-MOL81 485 1337-UM-1.4-EN
7/20
•
MOL81 485 1337: The presence of metal in the device vicinity must be strictly controlled:
•
MOL81 485 1312:
a
a
Fig. 1
Fig. 2
Fig. 3
In order to guarantee correct range:
•
The device must be mounted directly onto a metallic
plate which extends at least 10cm (a) beyond the
base in both directions
•
Beyond this distance, the device can be recessed
(see figure 2), but not deeper than the height of the
case
a
a
In order to guarantee correct range:
•
The device must not be installed directly on
metal and can be mounted directly onto
wooden sleepers. Metallic masses shall be
distant of at least 10 cm (a).
•
Beyond this distance, the device can be
recessed (see figure 2), but not deeper
than the height of the case.
Fig. 1
Fig. 2
Fig. 3