VI. ERROR/ADVISORY CODES

Should the Duo Charge sense an error condition, the specific cause of error will be indicated on the display.
Conditions and their indicators are by a system of intermittant blinks on Green LED #4, as described below:

CONDITION

NUMBER OF BLINKS

SYSTEM TEMPERATURE TOO HIGH

ONE BLINK

START BATTERY TOO HIGH VOLTAGE

TWO BLINKS

HOUSE BATTERY TOO LOW VOLTAGE

THREE BLINKS

HOUSE BATTERY TOO HIGH VOLTAGE

FOUR BLINKS

BATTERY TEMPERATURE TOO HIGH

FIVE BLINKS

VOLTAGE AT ON/OFF CIRCUIT TOO LOW

SIX BLINKS

If an error condition exists that cannot be corrected through repair or replacement of the system wiring, contact the
Balmar Customer Service department at 360-435-6100. Should your Duo Charge require replacement under warran-
ty, a Return Authorization will be assigned by a Customer Service representative. Do not return the product without
prior authorization. Please include a copy of the original purchase receipt with the unit and note the Return

PROGRAMMING FOR CHARGING VOLTAGE

While we do recommend using the preset programs in most circumstances, the Duo Charge can be programmed
based on upper and lower voltage values. To change lower limits, activate the switch when the #1 (Amber) LED is lit
as described in Step #3. Voltage values will be indicated as shown in the chart in Section VII. To change upper lim-
its, activate the switch when the #2 (Amber) LED is lit as described in Step #3. Voltage values will be indicated as
shown on the following page. 