![Balmar Centerfielder II Installation And Operation Manual Download Page 3](http://html1.mh-extra.com/html/balmar/centerfielder-ii/centerfielder-ii_installation-and-operation-manual_3588509003.webp)
3
www.balmar.net / Customer Service: +1 (360) 435-6100 x1 / Technical Support: +1 (360) 435-6100 x3
Tech Service is available Monday - Friday (8:30am - 7:30pm EST)
CFII-12/24 Regulator Terminal Layout
1.
PORT REGULATOR FIELD INPUT TERMINAL
2.
PORT ALTERNATOR FIELD OUTPUT
TERMINAL
3.
PORT “IGNITION ACTIVATED” LED (RED)
4.
PORT REGULATOR IGNITION
5.
PORT IGNITION INPUT
6.
PORT REGULATOR DASH LAMP TERMINAL
7.
PORT DASH LAMP TERMINAL
8.
PORT “DASH LAMP” LED (RED)
9.
GROUND TERMINAL
10.
STARBOARD “DASH LAMP: LED (GREEN)
11.
STARBOARD REGULATOR DASH LAMP
TERMINAL
12.
STARBOARD DASH LAMP TERMINAL
13.
COMMUNICATIONS PORT
14.
COMMUNICATIONS PORT
15.
COMMUNICATIONS PORT
16.
STARBOARD IGNITION INPUT
17.
STARBOARD REGULATOR IGNITION
18.
STARBOARD “IGNITION ACTIVATED” LED
(GREEN)
19.
STARBOARD ALTERNATOR FIELD OUTPUT
TERMINAL (MASTER)
20.
STARBOARD REGULATOR FIELD INPUT
TERMINAL (MASTER)
21.
“COMBINE” LED (AMBER)
6
5
4
7
2
1
8
9
10
3
11
12
13
14
15
16
18
19
20
21
1.
PORT REGULATOR FIELD INPUT TERMINAL -
Connect Terminal #1 to port voltage regulator’s Field Output terminal
via a user-supplied 12-gauge BLUE wire. A female 1/4” spade terminal is supplied for connection to Terminal #1. The 12-
gauge BLUE wire will replace the regulator’s 14-gauge field wire.
2.
PORT ALTERNATOR FIELD OUTPUT TERMINAL -
Connect Terminal #2 to the port alternator’s field input terminal
via a user supplied 12-gauge BLUE wire. A female 1/4” spade terminal is supplied for connection to Terminal #2. Alternator-
side termination will vary based on alternator, and may require a user-supplied spade or ring terminal connector, depending
on the alternator configuration.
3.
PORT “IGNITION ACTIVATED” LED (RED) -
Indicates activation of port voltage regulator’s ignition wire. If LED is
illuminated, but the port voltage regulator is inactive, check for voltage at the regulator’s ignition terminal.
4.
PORT REGULATOR IGNITION
- Connect Terminal #4 to the port voltage regulator’s BROWN ignition wire. A BROWN 14-
Gauge user-supplied wire is recommended. A female 1/4” spade terminal is supplied with the Centerfielder II.
5.
PORT IGNITION INPUT
- Connect Terminal #5 to the port engine ignition switch or port engine oil pressure switch.
Terminal #5 must see zero volts when the port engine is turned off, and battery voltage when the port engine is running.
BROWN 14-Gauge user-supplied wire is recommended. A female 1/4” spade terminal is supplied for connection to
Terminal.