background image

BTL5-A/C/E/G_ _-M/U_ _ _ _-P-S 32/KA_ _

http://www.balluff.de

http://www.balluff.de

Technical Description
User's Guide

english

Summary of Contents for Micropulse BTL5-E series

Page 1: ...BTL5 A C E G_ _ M U_ _ _ _ P S 32 KA_ _ http www balluff de http www balluff de Technical Description User s Guide english ...

Page 2: ...er application 2 1 2 Qualified personnel 2 1 3 Use and inspection 2 1 4 Scope 2 2 Function and Characteristics 3 2 1 Characteristics 3 2 2 Function 3 2 3 Available stroke lengths and magnets 3 3 Installation 3 3 1 Transducer installation 3 3 2 Floating magnets 4 3 3 Captive magnets 5 4 Wiring 6 5 Startup 7 5 1 Check connections 7 5 2 Turning on the system 7 5 3 Check output values 7 5 4 Check func...

Page 3: ...power supply is via a cable which depending on the ver sion is either fixed or connected using a female connector Dimensions for installing the Micropulse transducer and for the magnets and control arm are found on pages 4 and 5 2 Function and Characteristics 3 1 Transducer installation Ensure that no strong electrical or magnetic fields are present in the immediate vicinity of the trans ducer Any...

Page 4: ...ng non magnetizable screws brass alumi num To ensure the accuracy of the transducer system the moving member must carry the magnet on a track parallel to the transducer The following table provides figures in mm for the spacing which must be maintained between magnet and transducer and for the permissible center offset Magnet type Distance D Offset C BTL5 P 3800 2 0 1 4 2 BTL5 P 5500 2 5 15 15 BTL...

Page 5: ...ws DIN 912 max tightening torque 2 Nm Nominal stroke Black round marking Magnet NL Fig 3 8 BTL2 GS10 _ _ _ _ A connecting rod Jam nut DIN 934 M5 Swivel eye DIN 648 Ball joint B DIN 71805 rotates hori zontally part of BTL5 F 2814 1S Ball joint B DIN 71805 rotates horizontally Black round marking Fig 3 6 BTL5 F 2814 1S magnet Fig 3 7 BTL5 M N 2814 1S magnet Mechanically joined to M5 stud using 2 nut...

Page 6: ...des only limited protection Cable length max 20 m Ø 6 to 8 mm Longer lengths may be used if construction shielding and routing are such that external noise fields will have no effect on signal integrity Fig 4 2 Pin assignments BKS connector type BTL BKS connector view towards solder side of female BKS S 32M 00 or BKS S 33M 00 Table 4 1 Wiring assignment straignt BKS S 32M 00 No 99 5672 19 08 Binde...

Page 7: ...cropulse Linear Transducer Voltage output 10 V increasing decreasing UA 10 V 0 V Current output 20 mA increasing decreasing IA 20 mA 0 mA for BTL5 C IA 20 mA 4 mA for BTL5 E 5 3 Check output values After replacing or repairing a trans ducer it is advisable to verify the values for the start and end position of the magnet in manual mode If values other than those present before the replacement or r...

Page 8: ... to 28 V Ripple 0 5 Vpp BTL5 _2 DC 14 7 to 15 3 V Current draw 150 mA Inrush 3 A 0 5 ms Polarity reversal protection built in Overvoltage protection Transzorb diodes Electric strength GND to housing 500 V 7 3 Outputs BTL5 A Output voltage 0 10 10 0 V Load current 5 mA Ripple 5 mV BTL5 G Outputvoltage 10 10 10 10 V Load current 5 mA Ripple 5 mV BTL5 C Output current 0 20 20 0 mA Load resistance 500...