66
Figure 7: wxPropView - Triggered acquisition with area-scan cameras
Note
With the property
"Divider"
you can set if every signal (or every second, third etc.) from the rotary encoder is
used.
1.14.1.5
Working with trigger events
One or many trigger(s) can be used to control start of an acquisition, of a frame of an acquisition or each line of a
frame (for line scan devices). It can also be used to control the exposure duration at the beginning of a frame.
MATRIX VISION GmbH