Installation and connection (continued)
4.2
Electrical Connection
Fig. 4-4:
4
2
1
3
Pin assignment of S75 connector
(view from above on connector of BIP)
Pin
Wire color
Signal
1
Brown
L+ (18…30 V)
2
–
Not used
1)
3
Blue
L– (GND)
4
Black
C/Q (communication line)
1)
Unassigned leads that are not used can be connected to the GND on
the controller side but not to the shield.
Tab. 4-2: Pin assignment of S75 connector
4.3
Cable routing
Defined ground!
The BIP and the control cabinet must be at the
same ground potential.
Magnetic fields
The BIP operates according to the eddy current principle.
It is important to maintain adequate distance between the
BIP and strong, external magnetic fields.
Cable routing
Do not route the cable between the BIP, controller, and
power supply near high voltage cables (inductive stray
noise is possible).
Inductive stray noise from AC harmonics (e.g. from phase
angle controls) are especially critical and the cable shield
offers very little protection against this.
Cable length
Cable length max. 20 m. Longer cables may be used if
their construction, shielding and routing prevent noise
interference.
BIP LD2-T_ _ _-03-S75
Inductive Positioning System
Summary of Contents for LD2-T048-03-S75
Page 2: ...www balluff com ...
Page 3: ...Betriebsanleitung BIP LD2 T_ _ _ 03 S75 deutsch ...
Page 4: ...www balluff com ...
Page 23: ...User s Guide BIP LD2 T_ _ _ 03 S75 english ...
Page 24: ...www balluff com ...
Page 43: ...Notice d utilisation BIP LD2 T_ _ _ 03 S75 français ...
Page 44: ...www balluff com ...
Page 63: ...Manuale d uso BIP LD2 T_ _ _ 03 S75 italiano ...
Page 64: ...www balluff com ...
Page 83: ...Manual de instrucciones BIP LD2 T_ _ _ 03 S75 español ...
Page 84: ...www balluff com ...
Page 103: ...操作手册 BIP LD2 T_ _ _ 03 S75 中文 ...
Page 104: ...www balluff com ...
Page 123: ...取扱説明書 BIP LD2 T_ _ _ 03 S75 日本語 ...
Page 124: ...www balluff com ...
Page 143: ......