Basic functions (continued)
6.6.2 Process Data Out
The sensor transfers one byte of process data to the
sensor.
Byte 0
7
6
5
4
3
2
1
0
reserved
Counter Reset
Byte 0
Bit
Parameter
name
Description
Value
1
0
0
Switch Count:
Counter Reset
Switch count
feature: Sets the
counter state to 0.
Reset
Idle
Tab. 6-9: Input data
BES M12M_1-YIC_0_-S04G