12
english
Fig. 4-8:
Supporting rod made of non-magnetizable material
Example 2, transducer installed with supporting rod
4.4
Electrical connection
The transducer is connected via a connector.
The pin assignments for the respective version can be
found in Tab. 4-2 and Tab. 4-3.
Note the information on shielding and cable
routing.
4.4.1 Connector BTL7-...-C003
Fig. 4-9:
3
1
4
4
1
2
2
3
1
4
2
3
Pin assignment of connector (view from above on
transducer)
Power
Pin
Cable color
Signal
1
BN brown
10…30 V DC
2
WH white
Not used
1)
3
BU blue
0 V GND
2)
4
BK black
Not used
1)
1)
Unassigned leads can be connected to the GND on the controller side
but not to the shield.
2)
Reference potential for supply voltage and EMC-GND.
Tab. 4-2: Pin assignment of ...-C003 connector, supply
Magnets
(e.g. BTL-P-1028-15R)
Power
(pin)
Bus OUT/
Port2
(socket)
Bus IN/
Port1
(socket)
4
Installation and connection (continued)
BUS IN/OUT (data)
Pin
Cable color
Signal
1
YE yellow
TX+
2
WH white
RX+
3
OG orange
TX−
4
BU blue
RX−
Tab. 4-3: Pin assignment of ...-C003 connector, BUS IN/OUT
4.5
Shielding and cable routing
Defined ground!
The transducer and the control cabinet must be
at the same ground potential.
Shielding
To ensure electromagnetic compatibility (EMC), observe
the following:
– Connect transducer and controller using a shielded
cable.
Shielding: Braided copper shield with minimum 85%
coverage.
– Shield is internally connected to connector housing.
Magnetic fields
The transducer system is a magnetostrictive system.
Ensure that there is sufficient distance between the
transducer and between the transducer/holding cylinder
and strong, external magnetic fields.
Cable routing
Do not route the cable between the transducer, controller,
and power supply near high voltage cables (inductive stray
noise is possible).
The cable must be routed tension-free.
Cable length
The maximum cable length when using CAT5e cables is
100 m
3)
.
3)
Prerequisite: Construction, shielding and routing preclude the effect of any
external noise fields.
BTL7-V50D-M _ _ _ _ -A/B/Y/Z(8)-C003
Transducer — Rod Style
Summary of Contents for BTL7-V50D-M P-C003 Series
Page 1: ...BTL7 V50D M_ _ _ _ A B Y Z 8 C003 Betriebsanleitung deutsch...
Page 2: ...www balluff com...
Page 21: ...BTL7 V50D M_ _ _ _ A B Y Z 8 C003 User s Guide english...
Page 22: ...www balluff com...
Page 41: ...BTL7 V50D M_ _ _ _ A B Y Z 8 C003 Manual de instrucciones espa ol...
Page 42: ...www balluff com...
Page 61: ...BTL7 V50D M_ _ _ _ A B Y Z 8 C003 Notice d utilisation fran ais...
Page 62: ...www balluff com...
Page 81: ...BTL7 V50D M_ _ _ _ A B Y Z 8 C003 Manuale d uso Italiano...
Page 82: ...www balluff com...