16
english
7.1
Accuracy
The specifications are typical values for BTL7-C/E… at
24 V DC and room temperature, with a nominal length of
500 mm in conjunction with the BTL5-P-3800-2,
BTL5-P-4500-1, BTL5-P-5500-2
1)
, BTL6-A-3800-2
1)
,
BTL6-A-3801-2
1)
, BTL5-F-2814-1S, BTL5-T-2814-1S,
BTL5-M-2814-1S or BTL5-N-2814-1S magnet.
The transducer is fully operational immediately, with full
accuracy after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Repeat accuracy
typical
±5 µm
Sampling rate
Dependent on the nominal length
At nominal length = 500 mm
250 µs
2)
…5.7 ms
500 µs
Non-linearity with a constant
distance between the magnet and
profile:
Nominal length ≤ 500 mm
Nominal length
> 500 to ≤ 5500 mm
Nominal length > 5500 mm
±50 µm
±0.01 % FS
±0.02 % FS
Temperature coefficient
3)
≤ 30 ppm/K
Min. detectable speed
3 mm/s
Max. detectable speed
10 m/s
7.2
Ambient conditions
Operating temperature
−40°C…+85°C
Operating temperature for UL
(only BTL7…-KA…)
Max. +80°C
Storage temperature
−40°C…+100°C
Relative humidity
< 90%,
non-condensing
Shock rating
Continuous shock
per EN 60068-2-27
5), 6)
150 g/6 ms
150 g/2 ms
Vibration
per EN 60068-2-6
5), 6)
20 g, 10…2000 Hz
Degree of protection per IEC 60529
Connector S32 (when attached)
IP67
Cable
IP68
5)
4)
7.3
Supply voltage (external)
Voltage, stabilized
7)
10…30 V DC
Ripple
≤ 0.5 V
SS
Current draw (at 24 V DC)
≤ 160 mA
Inrush current
≤ 500 mA
Reverse polarity protection
8)
Up to 36 V
(supply to GND)
Overvoltage protection
Up to 36 V
Dielectric strength
(GND to housing)
500 V AC
7.4
Output
BTL7-C5_ _
Output current
Max. configuration
9)
Factory setting
Load resistance
0…20 mA or 20…0 mA
0…20 mA or 20…0 mA
≤ 500 Ω
BTL7-E5_ _
Output current
Max. configuration
9)
Factory setting
Load resistance
0…20 mA or 20…0 mA
4…20 mA or 20…4 mA
≤ 500 Ω
Additional voltage output
Output voltage
Load current
0…10 V or 10…0 V
≤ 5 mA
Short circuit resistance
Signal cable to 36 V
Signal cable to GND
1)
In the position range from 0 to 20 mm, the specified linearity limit may be
exceeded by ±100 µm.
2)
Only position output. For speed output, next-higher measured value rate
(500 µs or 750 µs).
3)
Nominal length 500 mm, magnet in the middle of the measuring range
4)
For
: Use in enclosed spaces and up to a height of 2000 m above sea
level.
5)
Individual specifications as per Balluff factory standard
6)
Resonant frequencies excluded
7)
For
: The transducer must be externally connected via a limited-
energy circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1, or a class 2 power supply as defined in UL 1310 or
UL 1585.
8)
A prerequisite is that no current can flow between GND and 0 V in the
event of polarity reversal.
9)
Only with PC software (Micropulse Configuration Tool)
7
Technical data
BTL7-C/E5_ _-M _ _ _ _ -P-S32/KA _ _
Micropulse Transducer in a Profile Housing
Summary of Contents for BTL7-E508-M P-S32/KA Series
Page 2: ...www balluff com...