1
EU Directive 2004/108/EG (EMC Directive) and EMC law
Noise immunity: EN 61000-6-1 / EN 61000-6-2
Emission: EN 61000-6-3 / EN 61000-6-4
File No.
E227256
BTL7-C/E1-M _ _ _ _ -A/B/Y/Z(8)-SA42/327-KA_ _-ZA0C
Micropulse Transducer - Rod Style
english
Intended use
The BTL7 Micropulse Transducer, together with a machine
controller (e.g. PLC), comprises a position measuring
system. It is intended to be installed into a machine or
system. Flawless function in accordance with the
specifications in the technical data is ensured only when
using original BALLUFF accessories, use of any other
components will void the warranty.
Opening the transducer or non-approved use are not
permitted and will result in the loss of warranty and liability
claims against the manufacturer.
General safety notes
Installation and startup
may only be performed by
trained specialists.
The
operator
is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the position
measuring system will not result in hazards to persons or
equipment.
If defects and unresolvable faults occur in the transducer,
it should be taken out of service and secured against
unauthorized use.
User's guide download
A complete standard user's guide can be downloaded
from the Internet at
www.balluff.com/downloads-btl7
or requested via e-mail from
.
Dimensions and function
The transducer contains the waveguide. A magnet is
moved along the waveguide. This magnet defines the
position to be measured on the waveguide.
LED1
LED2 Operating state
Green
Off
Normal function (magnet is
within the measuring range)
Flashing
red
Not in measuring range (magnet is
outside the measuring range)
Red
Error (no magnet or magnet outside
the limits)
~47
M12
~27
~53
Ø D1
G
KA00,3 = 0.3 m cable length
Damping
zone
1)
Zero point
LED 1
LED 2
Thread size
B: M18x1.5
Z: 3/4"-16UNF
Thread size
A: M18x1.5
Y: 3/4"-16UNF
1)
Unusable area
2)
Not included
3)
Not included with SA327
BTL7...KA_ _
Magnet
2)
End point
Mounting surface
Mounting surface
Error signal
Output signal with increasing
characteristic:
100 %
0 %
Version
D1
G
...-A/B/Y/Z-...
10.2 mm
Thread
M4x4/6 deep
...-A8/B8/Y8/Z8-... 8 mm
Without thread
B: 30 – 1 mm
Z: 2"– 0.04"
A: 30 – 1 mm
Y: 2" – 0.04"
Nominal length
= Measuring range
Calibration device
3)