Balluff BTL7-C Series Condensed Manual Download Page 4

1

EU Directive 2004/108/EG (EMC Directive) and EMC law

Noise immunity: EN 61000-6-1 / EN 61000-6-2

Emission: EN 61000-6-3 / EN 61000-6-4

File No.

E227256

BTL7-C/E1-M _ _ _ _ -A/B/Y/Z(8)-SA42/327-KA_ _-ZA0C

Micropulse Transducer - Rod Style

english

Intended use

The BTL7 Micropulse Transducer, together with a machine 

controller (e.g. PLC), comprises a position measuring 

system. It is intended to be installed into a machine or 

system. Flawless function in accordance with the 

specifications in the technical data is ensured only when 

using original BALLUFF accessories, use of any other 

components will void the warranty.

Opening the transducer or non-approved use are not 

permitted and will result in the loss of warranty and liability 

claims against the manufacturer.

General safety notes

Installation and startup

 may only be performed by 

trained specialists.

The 

operator

 is responsible for ensuring that local safety 

regulations are observed. In particular, the operator must 

take steps to ensure that a defect in the position 

measuring system will not result in hazards to persons or 

equipment.

If defects and unresolvable faults occur in the transducer, 

it should be taken out of service and secured against 

unauthorized use.

User's guide download

A complete standard user's guide can be downloaded 

from the Internet at  

www.balluff.com/downloads-btl7

 

or requested via e-mail from  

[email protected]

.

Dimensions and function

The transducer contains the waveguide. A magnet is 

moved along the waveguide. This magnet defines the 

position to be measured on the waveguide.

LED1

LED2 Operating state

Green

Off

Normal function (magnet is

within the measuring range)

Flashing 

red

Not in measuring range (magnet is 

outside the measuring range)

Red

Error (no magnet or magnet outside 

the limits)

~47

M12

~27

~53

Ø D1

G

KA00,3 = 0.3 m cable length

Damping 

zone

1)

Zero point

LED 1

LED 2

Thread size

B: M18x1.5

Z: 3/4"-16UNF

Thread size

A: M18x1.5

Y: 3/4"-16UNF

1)

 Unusable area

2)

 Not included

3)

 Not included with SA327

BTL7...KA_ _

Magnet

2)

End point

Mounting surface

Mounting surface

Error signal

Output signal with increasing 

characteristic:

100 %

0 %

Version

D1

G

...-A/B/Y/Z-...

10.2 mm

Thread 

M4x4/6 deep

...-A8/B8/Y8/Z8-... 8 mm

Without thread

B: 30 – 1 mm

Z: 2"– 0.04"

A: 30 – 1 mm

Y: 2" – 0.04"

Nominal length

= Measuring range

Calibration device

3)

Reviews: