www.balluff.com
7
english
3.1
Construction
Electrical connection:
The electrical connection is made
via a cable or a connector (see Type code on page 21).
Housing:
Aluminum housing containing the waveguide
and processing electronics.
Magnet:
Defines the position to be measured on the
waveguide. Magnets are available in various models and
must be ordered separately (see Accessories on
Nominal length:
To optimally adapt the BTL to the
application, nominal lengths from 50 mm to 7620 mm are
available.
3
Construction and function
Fig. 3-1: BTL7-…, construction
12
72
73
~80
~80
~250
~250
15
50
35
68
41
36.8
~23
max. 7
1) Unusable area
2) Not included in scope
of delivery
1)
Nominal length =
Measuring range
Null point
End point
Output signal rising:
Error signal
100 %
0 %
BTL5-P-3800-2 magnet
1)
Mounting clamps with insulating bushes
and ISO 4762 M5x22 cylinder-head screws,
max. tightening torque 2 Nm
2)
2)
BTL7-…-S32
BTL7-…-KA_ _
Groove
BTL7-C/E5_ _-M _ _ _ _ -P-S32/KA _ _
Magnetostrictive Linear Position Sensor – Profile Style
Summary of Contents for BTL7-C/E509-M Series
Page 2: ...www balluff com...
Page 4: ...www balluff com...
Page 26: ...www balluff com...
Page 48: ...www balluff com...
Page 70: ...www balluff com...
Page 92: ...www balluff com...
Page 114: ...www balluff com...
Page 116: ...4 9 21 10 22 10 1 22 10 2 22 BTL7 C E5_ _ M _ _ _ _ P S32 KA _ _...
Page 118: ...6 2 1 BTL PLC Balluff BTL 2 2 2 3 BTL BTL 2 4 2 5 2 BTL7 C E5_ _ M _ _ _ _ P S32 KA _ _...
Page 125: ...www balluff com 13 5 5 1 1 2 3 BTL BTL 5 2 BTL BTL BTL7 C E5_ _ M _ _ _ _ P S32 KA _ _...
Page 135: ......