BTL5-S1_ _-M/U_ _ _ _-K-SR32/K_ _
Micropulse Linear Transducer - Rod Style
2
english
Contents
1
Safety Advisory ..................... 2
1.1 Proper application .................. 2
1.2 Qualified personnel ................ 2
1.3 Use and inspection ................ 2
1.4 Scope ..................................... 2
2
Function and
Characteristics ..................... 3
2.1 Characteristics ....................... 3
2.2 Function ................................. 3
2.3 Available stroke lengths
and magnets .......................... 3
3
Installation ............................ 3
3.1 Mounting ................................ 3
3.2 Transducer, Installation ........... 4
3.3 Magnets, Installation .............. 5
4
Wiring .................................... 5
5
Startup ................................... 6
5.1 Check connections ................ 6
5.2 Turning on the system ............ 6
5.3 Check output values .............. 6
5.4 Check functionality ................ 6
5.5 Fault conditions ...................... 6
6
Technical Data ...................... 7
6.1 Dimensions, weights,
ambient conditions ................ 7
6.2 Supply voltage (external) ........ 7
6.3 Control signals ....................... 7
6.4 Connection to processor ........ 7
6.5 Included in shipment .............. 7
6.6 Magnets ................................. 7
6.7 Accessories ............................ 7
6.8 Compatible devices ............... 7
7
Versions (indicated
on part label) ......................... 7
Read this manual before installing
and operating the Micropulse Trans-
ducer.
1.1
Proper application
The BTL5 Micropulse transducer is
intended to be installed in a ma-
chine or system. Together with a
controller (PLC) it comprises a posi-
tion measuring system and may
only be used for this purpose.
Unauthorized modifications and
non-permitted usage will result in
the loss of warranty and liability
claims.
1.2
Qualified personnel
This guide is intended for special-
ized personnel who will perform the
installation and setup of the system.
1.3
Use and inspection
The relevant safety regulations must
be followed when using the trans-
1
Safety Advisory
ducer system. In particular, steps
must be taken to ensure that should
the transducer system become de-
fective no hazards to persons or
property can result. This includes
the installation of additional safety
limit switches, emergency shutoff
switches and maintaining the per-
missible ambient conditions.
1.4
Scope
This guide applies to the model
BTL5-S1...K... Micropulse trans-
ducer.
An overview of the various models
can be found in section 7 Versions
(indicated on product label) on
page 7.
Note:
For special versions, which
are indicated by an -SA_ _ _ des-
ignation in the part number, other
technical data may apply (affect-
ing calibration, wiring, dimensions
etc.).
The following patents have been
granted in connection with this
product:
US Patent 5 923 164
Apparatus and Method for Auto-
matically Tuning the Gain of an
Amplifier
US Patent 5 903 426
Overvoltage Protection Apparatus
for Data Interface
Emission tests:
RF Emission
EN 55011
Group 1, Class A
Noise immunity tests:
Static electricity (ESD)
EN 61000-4-2
Severity level 3
Electromagnetic fields (RFI)
EN 61000-4-3
Severity level 3
Fast transients (Burst)
EN 61000-4-4
Severity level 3
Surge
EN 61000-4-5
Severity level 2
Line-induced noise induced by
high-frequency fields
EN 61000-4-6
Severity level 3
Magnetic fields
EN 61000-4-8
Severity level 4
The CE Mark verifies
that our products meet
the requirements of
EC Directive
89/336/EEC (EMC Directive)
and the EMC Law. Testing in our
EMC Laboratory, which is accred-
ited by DATech for Testing Electro-
magnetic Compatibility, has con-
firmed that Balluff products meet
the EMC requirements of the fol-
lowing Generic Standards:
EN 50081-2 (emission)
EN 61000-6-2 (noise immunity)