www.balluff.com
25
english
3
Overview of IO-Link Data and Functions (continued)
3.5
System Commands
Command Value
Device Action
0x40 (64)
Teach Apply
– Calculates the switching point for SP1, SP2.
0x41 (65)
Teach SP1
– Determines teach point 1 for setpoint 1 and calculates the switching point.
0x42 (66)
Teach SP2
– Determines teach point 1 for setpoint 2 and calculates the switching point.
0x43 (67)
Teach SP1 TP1
– Determines teach point 1 for setpoint 1
0x44 (68)
Teach SP1 TP2
– Determines teach point 2 for setpoint 1
0x45 (69)
Teach SP2 TP1
– Determines teach point 1 for setpoint 2
0x46 (70)
Teach SP2 TP2
– Determines teach point 2 for setpoint 2
0x47 (71)
Teach SP1 Start
– Starts dynamic teach-in for setpoint 1
0x48 (72)
Teach SP1 Stop
– Stops dynamic teach-in for setpoint 1 and calculates the switching point.
0x49 (73)
Teach SP2 Start
– Starts dynamic teach-in for setpoint 2
0x4A (74)
Teach SP2 Stop
– Stops dynamic teach-in for setpoint 2 and calculates the switching point.
0x4E (78)
Teach Reset
– Any active teach-in process is interrupted, all temporarily stored values are reset.
0x4F (79)
Teach Cancel
– Any active teach-in process is interrupted.
0x80 (128)
Device Reset
– Device Reset means a warm start of the device. During this process, the
microcontrollers are restarted and all initializations performed again without any change made to
the parameter values (see chapter 7.3 on page 92).
0x81 (129)
Application Reset
0x82 (130)
Restore Factory Settings
0xA5 (165)
Maintenance Reset
0xA6 (166)
Switching Counter Reset
– Resets counter value and flags.
0xA7 (167)
Statistics Reset
– Resets all output parameters to 0 and all user settings to the default values.
0xA8 (168)
Statistics Start Min/Max/Avg
– Starts the statistics of the minimum value/maximum value/average
calculation.
0xA9 (169)
Statistics Stop
– Stops statistics operation completely.
0xAA (170)
Signal Speed Monitoring Reset
– Resets the speed value and flags.
0xAC (172)
Statistics Start Moving Average
– Starts the statistics of the moving average calculation.
0xAF (175)
Start Device Discovery
0xC0 (192)
Set Reference Orientation
– Sets the reference orientation of the actual position of the device.
Responses: ACK: command successful, reference stored.
0xE0 (224)
Teach Preset
– Sets the current measurement value to the value of
Measurement Preset
.
Tab. 3-3: System Commands – Overview
BOS R254K-UUI-RH11-S4
Photoelectric Sensors
Summary of Contents for BOS R254K-UUI-RH11-S4
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI RH11 S4...