82
english
The objective of this function is the detection of larger
vibration deviations that arise between normal and
abnormal operation as well as the detection of trends
(change of the values over time).
The accuracy of the measurement is limited by the
application, because the device is mounted to perform the
primary function (e.g., optical distance measurement) and
not as a sensor for vibration measurement. Thus, not only
are the vibrations of the vibration source that is to be
measured, but also the vibrations of the entire mechanical
system.
This function is based on the ISO-10816-3 standard, but
for a detailed vibration analysis Balluff offers special
sensors.
The product family is designed such that it offers complete
monitoring functionality, whereby the status monitoring is
the primary function of the sensor and it is mounted on the
object or on the machine.
Fig. 5-11: Trend analysis
5.13.3 Process Data
Object ID
Name
Description
Direction
0x004A (74)
Vibration Level
Vibration level
Input
0x004B (75)
Vibration Alarm Status
Vibration alarm status
Input
Tab. 5-62: Vibration detection – Process data
The unit for
Vibration Level
is [mm/s]
The vibration alarm status flag is without units.
5
Secondary Device Functions (continued)
BOS R080K-UIM-RE10-…
Photoelectric Sensors
Summary of Contents for BOS R080K-UIM-RE10 Series
Page 1: ...deutsch IO Link Konfiguration english IO Link Configuration BOS R080K UIM RE10...
Page 2: ...www balluff com...
Page 3: ...BOS R080K UIM RE10 IO Link Konfiguration deutsch...
Page 4: ...www balluff com...
Page 107: ...BOS R080K UIM RE10 IO Link Configuration english...
Page 108: ...www balluff com...
Page 211: ......