– Press + at the same time, to access the menu.
– In the menu navigate down with and up with .
– With
select or save the setting, with
navigate a level up.
– If the buttons are locked, press + for longer than 5 s.
– Exit: Press
in the main menu.
Switch output
Out 1
Out 2
Hysteresis
Main Menu:
Out 1
Out 2
Hysteresis
Main Menu:
Switching
logic
Q Logic
Switching Point
Output Mode
Output:
SET
ESC
Light
Dark
Q Logic:
SET
Save
Light: Light-switching
Dark: D a r k - s w i t c h i n g
Out 2 like Out 1
Switch
point
Q Logic
Switching Point
Output Mode
Output:
SET
ESC
SET
> 3 s
Save
Measurement where the
digital output changes the
status.
Output
mode
Q Logic
Switching Point
Output Mode
Output:
SET
ESC
PNP
NPN
Push Pull
Output Mode:
SET
Save
Select the topology of the
output load (PNP, NPN or
Push-Pull)
Alarm
Alarm
Output:
SET
ESC
ON
OFF
Alarm:
SET
Save
ON: the digital output
switches, if the value is out of
range.
OFF: the digital output does
not switch, if the value is out
of range.
Switching hysteresis
Out 1
Out 2
Hysteresis
Main Menu:
Keep
pressed for
longer than 1s and set
a number with /
(10…1000 mm)
SET
> 3 s
Save
Numerical value of hysteresis on the digital output.
Analog output
Analogue Out
Multifunction in
Average
Main Menu:
Voltage
Current
Analogue Out:
SET
Save
Set type of analog output:
Voltage: 0…10 V
Current: 4…20 mA
Keep
pressed for
longer than 1s and set
a number with /
(200…20000 mm).
ESC
Configuration
Operation
MIN
Low
High
V
MAX
mm
Distance
Hysteresis
Switchpoint
distance
Output Q1/Q2
Maintenance
We recommend cleaning the photoelectric surfaces and
checking the connector at regular intervals.
Switching hysteresis
3
english
BOD 37M-LPR02-S115
Photoelectric Sensors – Laser Distance Sensor