Balluff Network Interface
ProfiNet™
www.balluff.com
19
5
Integration
Module settings
Port functions
Safe state
Global diagnostics:
This function can be used to permit / suppress all diagnostics messages of the module.
(optical diagnostics signals and diagnostics in configured diagnostics modules
are not affected)
Sensor supply undervoltage:
This function can be used to permit / suppress the diagnostics message Sensor supply
undervoltage. (optical diagnostics and diagnostics in configured diagnostics modules are
not affected)
Actuator supply undervoltage:
This function can be used to permit / suppress the diagnostics message Actuator supply
undervoltage. (optical diagnostics signals and diagnostics in configured diagnostics
modules are not affected)
Sensor connection to output:
This function can be used to permit / suppress the diagnostics message Sensor Short-
circuit on the module output. (Visual diagnostics and diagnostics in configured diagnostics
modules is not affected) Function applies only to channels/pins which are configured as
outputs. Channels/pins configured as inputs are unaffected.
The function for every individual port pin can be defined here:
Make contact = input as normally open contact
Break contact = input as normally closed contact
Output = output function
IO-Link Input with SIO mode = SIO mode; one IO-Link device can be configured via IO-Link
and then moved to an SIO mode in which the IO-Link port
in functions as a simple switching input.
Pin function depending on configuration.
This function is a supplement to an output configuration of the respective port pin.
For each port pin, a safe status can be predefined which is assumed in the event of a
failure in bus communication.
5.2.
Functions in
module properties
Description of the functions in module properties